Omron Q2A Series Technical Manual page 707

Driving quality 400 v class 0.55 kw to 315 kw
Hide thumbs Also See for Q2A Series:
Table of Contents

Advertisement

Note:
• When L6-01 ≥ 5, the drive will detect when the output current/torque is less than the detection level of L6-02 for longer than the time
set in L6-03.
• Refer to "L6: TORQUE DETECTION" for more information.
33: TrqDetect1NC
Setting
Function
33
TrqDetect1NC
Use the L6 [Torque Detection] parameters to set torque detection.
OFF : The output current/torque is more than the torque value set with L6-02 [Trq Det1 Level], or
the level is less than the torque value set with L6-02 for longer than the time set with L6-03 [Trq
Det1 Time].
Note:
• When L6-01 ≥ 5, the drive will detect when the output current/torque is less than the detection level of L6-02 for longer than the time
set in L6-03.
• Refer to "L6: TORQUE DETECTION" for more information.
37: TrqDetect2NO
Setting
Function
37
TrqDetect2NO
Use the L6 [Torque Detection] parameters to set torque detection.
ON : The output current/torque is more than the torque value set with L6-05 [Trq Det2 Level], or
the level is less than the torque value set with L6-05 for longer than the time set with L6-06 [Trq
Det2 Time].
Note:
• When L6-04 ≥ 5, the drive will detect when the output current/torque is less than the detection level of L6-05 for longer than the time
set in L6-06.
• Refer to "L6: TORQUE DETECTION" for more information.
38: TrqDetect2NC
Setting
Function
38
TrqDetect2NC
Use the L6 [Torque Detection] parameters to set torque detection.
OFF : The output current/torque is more than the torque value set with L6-05 [Trq Det2 Level], or
the level is less than the torque value set with L6-05 for longer than the time set with L6-06 [Trq
Det2 Time].
Note:
• When L6-04 ≥ 5, the drive will detect when the output current/torque is less than the detection level of L6-05 for longer than the time
set in L6-06.
• Refer to "L6: TORQUE DETECTION" for more information.
39: Timer Output
Setting
Function
39
Timer Output
Note:
Refer to "b4: TIMER" for more information.
3C: Comparator 1
Setting
Function
3C
Comparator 1
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the drive detects overtorque or undertorque.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the drive detects overtorque or undertorque.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the drive detects overtorque or undertorque.
V/f
CL-V/f
OLV
CLV
AOLV
Use this setting when the drive uses the timer function as an output terminal.
V/f
CL-V/f
OLV
CLV
AOLV
The monitor value set with H2-20 [Compare1 Mon.Selection] is on while in range of the time set with H2-24 [Compare1 On-
Delay Time] and the values of H2-21 [Compare1 Low Limit] and H2-22 [Compare1 Up Limit] are in range.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
12.7 H: TERMINALS
707
12