F3-20 DA Function Selection
No.
Name
(Hex.)
F3-20
DA Function Selection
(0BED)
Expert
F3-21 DB Function Selection
No.
Name
(Hex.)
F3-21
DB Function Selection
(0BEE)
Expert
F3-22 DC Function Selection
No.
Name
(Hex.)
F3-22
DC Function Selection
(0BEF)
Expert
F3-23 DD Function Selection
No.
Name
(Hex.)
F3-23
DD Function Selection
(0BF0)
Expert
F3-24 DE Function Selection
No.
Name
(Hex.)
F3-24
DE Function Selection
(0BF1)
Expert
F3-25 DF Function Selection
No.
Name
(Hex.)
F3-25
DF Function Selection
(0BF2)
Expert

F4: ANALOG OUTPUT

F4 parameters set drive operation when you use analog monitor option card AO-A3. The AO-A3 card has 2
output terminals (terminals V1 and V2) for signals with an Output resolution of 11 bits (1/2048) + encoding and
that have an output voltage range of -10 V to +10 V. Install the AO-A3 card to a drive to output analog signals
that monitor the output status of the drive (output frequency and output current).
Refer to the AO-A3 card manual for more information about how to install, wire, and set the AO-A3 card.
Use the U monitor number to set the monitor data to be output from terminals V1 and V2 on the AO-A3 card.
Enter the last three digits of Ux-xx as the setting value.
• Use Gain and Bias to Adjust the Output Signal Level of Terminal V1
You must stop the drive to adjust the output signal. Use this procedure to calibrate the drive:
1. View the F4-02 [Term.V1 Gain] value on the keypad.
Terminal V1 will output a voltage = 100% of the monitor set in F4-01 [Term.V1 Funct Selection].
2. View the monitor connected to terminal V1 and adjust F4-02.
3. View the F4-05 [Term.V1 Bias] value on the keypad.
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for terminal DA of the DI-A3 when F3-01 = 8 [D.In Funct Selection = MF
Digital Input]
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for terminal DB of the DI-A3 when F3-01 = 8 [D.In Funct Selection = MF
Digital Input].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for terminal DC of the DI-A3 when F3-01 = 8 [D.In Funct Selection = MF
Digital Input].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for terminal DD of the DI-A3 when F3-01 = 8 [D.In Funct Selection = MF
Digital Input].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for terminal DE of the DI-A3 when F3-01 = 8 [D.In Funct Selection = MF
Digital Input].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for terminal DF of the DI-A3 when F3-01 = 8 [D.In Funct Selection = MF
Digital Input].
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
12.6 F: OPTIONS
Default
(Range)
0
(0 - 4, 6 - 19F)
Default
(Range)
0
(0 - 4, 6 - 19F)
Default
(Range)
0
(0 - 4, 6 - 19F)
Default
(Range)
0
(0 - 4, 6 - 19F)
Default
(Range)
0
(0 - 4, 6 - 19F)
Default
(Range)
0
(0 - 4, 6 - 19F)