11.10 n: SPECIAL
No.
Name
(Hex.)
n8-79
Pull-In
Curr@Deceleration
(05FE)
n8-84
Polarity Det Current
(02D3)
Expert
n8-94
FluxPos Est.Method
(012D)
Expert
n8-95
FluxPos Est.Filter Time
(012E)
Expert
462
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets, the pull-in current allowed to flow during deceleration as a percentage of the
motor rated current.
Note:
When n8-79 = 0, the drive will use the value set in n8-51 [Ac/Dec Pull-In Current].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the current that the drive uses to estimate the initial motor magnetic pole as a
percentage where E5-03 [PM Mot Rated Current (FLA)] = 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the criteria that the drive uses to find changes in speed or load. Usually it is not
necessary to change this setting.
1 : Softstarter
2 : Speed Feedback
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time constant of the filter used for the recognition criteria value for speed and
load changes. Usually it is not necessary to change this setting.
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Default
Ref.
(Range)
0%
803
(0 - 200%)
100%
803
(0 - 150%)
Determined by d5-01
803
(1, 2)
30 ms
803
(0 - 100 ms)

Hide quick links: