Omron Q2A Series Technical Manual page 313

Driving quality 400 v class 0.55 kw to 315 kw
Hide thumbs Also See for Q2A Series:
Table of Contents

Advertisement

CAUTION! Burn Hazard. Do not touch a hot drive heatsink. De-energize the drive, wait 15 minutes minimum, and make sure
that the heatsink is cool to replace the cooling fans. Failure to obey can cause minor to moderate injury.
NOTICE: Follow cooling fan replacement instructions. Replace all fans when performing maintenance to help ensure maximum
useful product life. Improper fan replacement could cause damage the drive.
Remove a Fan
1.
To remove the fan finger guard from the drive, push the hook on the back side of the fan finger guard and
pull up.
A - Fan finger guard
2.
Pull the cooling fan straight up from the drive. Disconnect the power supply connector and remove the fan
from the drive.
A - Cooling Fan
Install a Fan
Reverse the removal procedure to install a cooling fan.
1.
Connect the drive and the fan connector.
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Figure 8.7 Remove the Fan Finger Guard
Figure 8.8 Remove the Cooling Fan
Figure 8.9 Connect the Power Supply Connector
8.4 Replace a Cooling Fan and Circulation Fan
8
313