You cannot set the Reference Sample Hold function at the same time as these functions:
• H1-xx = 17 [Ac/Dec Hold]
• H1-xx = 62, 63 [Up Command, Down Command]
• H1-xx = 0E to 10 [ to Offset Frq 3]
• H1-xx = 65, 66 [Up2 Command, Dw2 Command]
If you set them at the same time, the drive will detect oPE03 [Multi-Function Input Setting Err].
17: Ac/Dec Hold
Setting
Function
17
Ac/Dec Hold
If the terminal is deactivated, the drive restarts acceleration and deceleration.
When the acceleration/deceleration ramp hold terminal is activated and d4-01 = 1 [FRef Hold Selection =
Enabled], the drive will store the output frequency in memory. While the acceleration/deceleration ramp hold
command is activated, the drive will always restart the motor at this output frequency.
Note:
"d4-01 FRef Hold Selection on page
Refer to
18: Ac/Dec Time1
Setting
Function
18
Ac/Dec Time1
Note:
Refer to "C1: ACCEL / DECEL" for more information.
19: Ac/Dec Time2
Setting
Function
19
Ac/Dec Time2
Note:
Refer to "C1: ACCEL / DECEL" for more information.
1A: Drive Enable
Setting
Function
1A
Drive Enable
If you input the Run command before you turn ON the Drive Enable terminal, you must input the Run command
again to operate the drive. When the terminal set for Drive Enable is turned OFF when the drive is operating, the
drive will use the stopping method set in b1-03 [Stopping Method Selection] to stop the motor.
ON : Run command is accepted.
OFF : Run command is disabled. When the drive is running, it stops according to b1-03 setting.
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Figure 12.76 Reference Sample Hold
V/f
CL-V/f
OLV
CLV
AOLV
Momentarily pauses motor acceleration and deceleration when the terminal is turned ON, retains the output frequency that was
stored in the drive at the time of the pause, and restarts motor operation.
596" for more information.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the drive to use C1-01, C1-02 [Accel Time 1, Decel Time 1] or C1-03, C1-04 [Accel Time 2, Decel Time 2].
V/f
CL-V/f
OLV
CLV
AOLV
Set this function and H1-xx = 18 [Ac/Dec Time1] together. Sets the drive to use C1-05, C1-06 [Accel Time 3, Decel Time 3] or
C1-07, C1-08 [Accel Time 4, Decel Time 4].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to show dnE [Drive Enabled] on the keypad and ignore Run commands when the terminal is OFF.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
12.7 H: TERMINALS
675