7.4 Faults
Code
Name
Note:
• This fault occurs if the drive sensors detect a drive output current more than the specified overcurrent detection level.
• Do a Fault Reset to clear the fault.
Code
Name
oFA00
Option Not Compatible with Port
Note:
• Do a Fault Reset to clear the fault.
• Fault trace is not available for this fault.
Code
Name
oFA01
Option Fault/Connection Error
Note:
Do a Fault Reset to clear the fault.
Code
Name
oFA02
Duplicate Options
Note:
Do a Fault Reset to clear the fault.
Code
Name
oFA03 to
Option Card Error Occurred at
oFA06
Option Port CN5-A
Note:
Do a Fault Reset to clear the fault.
Code
Name
Option Card Error Occurred at
oFA10, oFA11
Option Port CN5-A
Note:
Do a Fault Reset to clear the fault.
Code
Name
oFA12 to
Option Card Connection Error
oFA17
(CN5-A)
Note:
Do a Fault Reset to clear the fault.
Code
Name
oFA30 to
Communication Option Card
oFA43
Connection Error (CN5-A)
Note:
Do a Fault Reset to clear the fault.
262
Causes
If the drive detects the fault at start or in the low
speed range (10% or less) and n8-57 = 1 [High-
Freq Injection = Enabled] for PM Control methods,
the high frequency injection gain is too high.
The current flowing in the motor is more than the
value set in L8-27 [OverCurr Det Gain] for PM
Control.
The control method is set incorrectly for the motor.
The motor main circuit cable is too long.
Speed search does not complete at start when you
use an induction motor in EZOLV control.
Causes
The option card connected to connector CN5-A is
not compatible.
Causes
The option card connected to connector CN5-A is
not compatible.
Causes
The same option cards or the same type of option
cards are connected to connectors CN5-A, B, and C.
Causes
A fault occurred in the option card.
Causes
A fault occurred in the option card.
Causes
A fault occurred in the option card.
Causes
A fault occurred in the option card.
Possible Solutions
• Set E5: PM MOTOR SETTINGS correctly or do Rotational
Auto-Tuning.
• Decrease the value of n8-41 [HFI PoleDet Pgain] in 0.5 unit
increments.
Note:
Set n8-41 > 0.0 for IPM motors.
Correct the value set in L8-27.
Set A1-02 [Control Method] correctly.
Replace the drive with a larger capacity model.
When E9-01 = 0 [Motor Type Selection = IM], set b3-24 = 2
[SpSrch Method Selection = Current Det2].
Possible Solutions
Connect the option card to the correct connector.
Note:
Encoder option cards are not compatible with connector CN5-
A.
Possible Solutions
1.
De-energize the drive.
2.
Refer to the option card manual and correctly connect the
option card to the connector on the drive.
Possible Solutions
Connect the option card to the correct connector.
Note:
Use connectors CN5-C and CN5-B to connect two encoder
option cards.
Possible Solutions
1.
De-energize the drive.
2.
Make sure that the option card is correctly connected to the
connector.
3.
If the problem continues, replace the option card.
Possible Solutions
1.
De-energize the drive.
2.
Make sure that the option card is correctly connected to the
connector.
3.
If the problem continues, replace the option card.
Possible Solutions
1.
De-energize the drive.
2.
Make sure that the option card is correctly connected to the
connector.
3.
If the problem continues, replace the option card.
Possible Solutions
1.
De-energize the drive.
2.
Make sure that the option card is correctly connected to the
connector.
3.
If the problem continues, replace the option card.