Reattach The Front Cover Of Drive Models 4208 - 4675 - Omron Q2A Series Technical Manual

Driving quality 400 v class 0.55 kw to 315 kw
Hide thumbs Also See for Q2A Series:
Table of Contents

Advertisement

2.7 Removing/Reattaching Covers
4.
Loosen the front cover screws.
5.
Push on the four tabs found on each side of the front cover, then pull the front cover forward to remove it
from the drive.
A - Pull forward to remove the front
6.
Remove the front cover from the drive.

Reattach the Front Cover of Drive Models 4208 - 4675

Wire the drive and other peripheral devices then reattach the front cover.
Note:
Wire the grounding terminals first, main circuit terminals next, and control circuit terminals last.
DANGER! Electrical Shock Hazard. Do not examine, connect, or disconnect wiring on an energized drive. Before servicing,
disconnect all power to the equipment and wait for the time specified on the warning label at a minimum. The internal capacitor
stays charged after the drive is de-energized. The charge indicator LED extinguishes when the DC bus voltage decreases
below 50 Vdc. When all indicators are OFF, remove the covers before measuring for dangerous voltages to make sure that the
drive is safe. Failure to obey will cause death or serious injury.
44
Figure 2.26 Loosen the Front Cover Screws
cover.
Figure 2.27 Pull Forward to Remove the Front Cover
Figure 2.28 Remove the Front Cover
B - Unhook the tabs found on the
sides of the front cover.
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual

Hide quick links:

Advertisement