11.6

E: MOTOR

E1: V/F PARAMETER MOTOR 1

No.
Name
(Hex.)
E1-01
Input AC Supply Voltage
(0300)
E1-03
V/f Pattern Selection
(0302)
E1-04
Max Output Frequency
(0303)
E1-05
Max Output Voltage
(0304)
E1-06
Base Frequency
(0305)
E1-07
Mid A Frequency
(0306)
E1-08
Mid A Voltage
(0307)
E1-09
Min Output Frequency
(0308)
E1-10
Min Output Voltage
(0309)
E1-11
Mid B Frequency
(030A)
Expert
E1-12
Min Output Voltage
(030B)
Expert
E1-13
Base Voltage
(030C)
Expert
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the drive input voltage.
NOTICE: Set this parameter to align with the drive input
voltage (not motor voltage). The protective features of the
drive will not function if this parameter is incorrect. Failure to
obey will cause incorrect drive operation.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the V/f pattern for the drive and motor. You can use one of the preset patterns or
you can make a custom pattern.
0 : CT_50-50Hzmax
1 : CT_60-60Hzmax
2 : CT_50-60Hzmax
3 : CT_60-72Hzmax
4 : VT_50-35HzmidV
5 : VT_50-50HzmidV
6 : VT_60-35HzmidV
7 : VT_60-50HzmidV
8 : HT_50Hz_125 V
9 : HTrq50Hz-165 V
A : HTrq60Hz-125V
B : HT_60Hz-165V
C : HF_60-90Hzmax
D : HF_60-120Hzmax
E : HF_60-180Hzmax
F : (F) : Custom
Note:
• When A1-02 = 2 [Control Method = OLVector], settings 0 through E are not
available.
• Set the correct V/f pattern for the application and operation area. An incorrect V/f
pattern can decrease motor torque and increase current from overexcitation.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the maximum output frequency for the V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the maximum output voltage for the V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the base frequency for the V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a middle output frequency for the V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a middle output voltage for the V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum output frequency for the V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum output voltage for the V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a middle output frequency for the V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets minimum output voltage for the V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the base voltage for the V/f pattern.
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM

11.6 E: MOTOR

Default
Ref.
(Range)
400 V: 400 V
610
(400 V Class: 310 to 510
V)
F
610
(Determined by A1-02)
Determined by A1-02
615
and E5-01
(Determined by A1-02
and E5-01)
Determined by A1-02
615
(400 V Class: 0.0 - 510.0
V)
Determined by A1-02
615
and E5-01
(0.0 - E1-04)
Determined by A1-02
615
(0.0 - E1-04)
Determined by A1-02,
616
C6-01 and o2-04
(400 V Class: 0.0 to
510.0 V)
Determined by A1-02
616
and E5-01
(Determined by A1-02,
E1-04, and E5-01)
Determined by A1-02
616
0.0 Hz
616
(0.0 - E1-04)
0.0 V
616
0.0 V
616
415