H3: Analog Inputs - Omron Q2A Series Technical Manual

Driving quality 400 v class 0.55 kw to 315 kw
Hide thumbs Also See for Q2A Series:
Table of Contents

Advertisement

Setting
Function
67
ModbusReg 1
69
ModbusReg 2
6A
DataLog Error
90 to 93
Q2pack DO1 to 4
A0 to A7
Q2pack ExDO1 to 8
100 to 1A7
Inverse Output of 0 to
A7

H3: ANALOG INPUTS

No.
Name
(Hex.)
H3-01
AI1 Signal Level Select
(0410)
H3-02
AI1 Function Selection
(0434)
H3-03
AI1 Gain Setting
(0411)
RUN
H3-04
AI1 Bias Setting
(0412)
RUN
H3-05
AI3 Signal Level Select
(0413)
H3-06
AI3 Function Selection
(0414)
H3-07
AI3 Gain Setting
(0415)
RUN
H3-08
AI3 Bias Setting
(0416)
RUN
H3-09
AI2 Signal Level Select
(0417)
H3-10
AI2 Function Selection
(0418)
H3-11
AI2 Gain Setting
(0419)
RUN
H3-12
AI2 Bias Setting
(041A)
RUN
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the bit specified by H2-08 [Mbus Reg1 Bit Select] for the Modbus register address set
with H2-07 [Mbus Reg1 Address Select] activates.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the bit specified by H2-10 [Mbus Reg2 Bit Select] for the Modbus register address set
with H2-09 [Mbus Reg2 Address Select] activates.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the drive detects a LoG [Com Error / Abnormal SD card].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Q2pack digital output. Refer to the Q2pack online manual for more information.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the digital output for the Q2pack DO-A3 option card. Refer to the Q2pack online manual for more
information.
V/f
CL-V/f
OLV
CLV
AOLV
Causes inverse output of the function for the selected MFDO. Uses the last two digits of 1xx to select which
function to inversely output.
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the input signal level for MFAI terminal AI1.
0 : 0 to 10V (Lower Limit at 0)
1 : -10 to +10V (Bipolar Reference)
2 : 4 to 20 mA
3 : 0 to 20 mA
V/f
CL-V/f
OLV
CLV
AOLV
Sets a function for MFAI terminal AI1.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain of the analog signal input to MFAI terminal AI1.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the bias of the analog signal input to MFAI terminal AI1.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the input signal level for MFAI terminal AI3.
0 : 0 to 10V (Lower Limit at 0)
1 : -10 to +10V (Bipolar Reference)
2 : 4 to 20 mA
3 : 0 to 20 mA
V/f
CL-V/f
OLV
CLV
AOLV
Sets a function for MFAI terminal AI3.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain of the analog signal input to MFAI terminal AI3.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the bias of the analog signal input to MFAI terminal AI3.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the input signal level for MFAI terminal AI2.
0 : 0 to 10V (Lower Limit at 0)
1 : -10 to +10V (Bipolar Reference)
2 : 4 to 20 mA
3 : 0 to 20 mA
V/f
CL-V/f
OLV
CLV
AOLV
Sets a function for MFAI terminal AI2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain of the analog signal input to MFAI terminal AI2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the bias of the analog signal input to MFAI terminal AI2.
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
11.8 H: TERMINALS
Ref.
710
710
711
711
711
711
Default
Ref.
(Range)
0
713
(0 - 3)
4
713
(0 - 32)
100.0%
713
(-999.9 - +999.9%)
0.0%
714
(-999.9 - +999.9%)
0
714
(0 - 3)
1
714
(0 - 32)
100.0%
714
(-999.9 - +999.9%)
0.0%
715
(-999.9 - +999.9%)
2
715
(0 - 3)
4
715
(0 - 32)
100.0%
715
(-999.9 - +999.9%)
0.0%
716
(-999.9 - +999.9%)
441