Omron Q2A Series Technical Manual page 324

Driving quality 400 v class 0.55 kw to 315 kw
Hide thumbs Also See for Q2A Series:
Table of Contents

Advertisement

8.4 Replace a Cooling Fan and Circulation Fan
3.
Put the cable in the recess of the drive.
A - Front of drive
4.
Hold the fan finger guard at an angle and put the connector tabs on the fan finger guard into the holes on
the drive.
Note:
When you install the cooling fan, make sure that you do not pinch cables between the fan finger guard and the drive.
A - Front of drive
B - Insertion area
5.
Push the hook on the back side of the fan finger guard and click it into place on the drive.
6.
Energize the drive and set o4-03 = 0 [Fan.Oper Setting = 0 h] to reset the cooling fan operation time.
324
Figure 8.38 Put the Cable in the Drive Recess
C - Connector tabs
Figure 8.39 Reattach the Fan Finger Guard
Figure 8.40 Reattach the Fan Finger Guard
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual