Omron Q2A Series Technical Manual page 429

Driving quality 400 v class 0.55 kw to 315 kw
Hide thumbs Also See for Q2A Series:
Table of Contents

Advertisement

No.
Name
(Hex.)
F7-64
PZD5 Write
(0784)
F7-65
PZD6 Write
(0785)
F7-66
PZD7 Write
(0786)
F7-67
PZD8 Write
(0787)
F7-68
PZD9 Write
(0788)
F7-69
PZD10 Write
(0789)
F7-70
PZD1 RD (StatWord)
(078A)
F7-71
PZD2 RD (OutFreq)
(078B)
F7-72
PZD3 Read
(078C)
F7-73
PZD4 Read
(078D)
F7-74
PZD5 Read
(078E)
F7-75
PZD6 Read
(078F)
F7-76
PZD7 Read
(0790)
F7-77
PZD8 Read
(0791)
F7-78
PZD9 Read
(0792)
F7-79
PZD10 Read
(0793)
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Modbus address for PZD5 (PPO output). A value of 0, 1, or 2 will disable the
PZD5 (PPO output) write operation to the Modbus register.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Modbus address for PZD6 (PPO output). A value of 0, 1, or 2 will disable the
PZD6 (PPO output) write operation to the Modbus register.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Modbus address for PZD7 (PPO output). A value of 0, 1, or 2 will disable the
PZD7 (PPO output) write operation to the Modbus register.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Modbus address for PZD8 (PPO output). A value of 0, 1, or 2 will disable the
PZD8 (PPO output) write operation to the Modbus register.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Modbus address for PZD9 (PPO output). A value of 0, 1, or 2 will disable the
PZD9 (PPO output) write operation to the Modbus register.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Modbus address for PZD10 (PPO output). A value of 0, 1, or 2 will disable the
PZD10 (PPO output) write operation to the Modbus register.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Modbus address for PZD1 (PPO Read). PZD1 (PPO input) functions as the
ZSW when F7-70 = 0.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Modbus address for PZD2 (PPO Read). PZD2 (PPO input) functions as the
HIW when F7-71 = 0.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Modbus address for PZD3 (PPO Read). A value of 0 will disable the PZD3
(PPO input) load operation from the Modbus register.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Modbus address for PZD4 (PPO Read). A value of 0 will disable the PZD4
(PPO input) load operation from the Modbus register.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Modbus address for PZD5 (PPO Read). A value of 0 will disable the PZD5
(PPO input) load operation from the Modbus register.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Modbus address for PZD6 (PPO Read). A value of 0 will disable the PZD6
(PPO input) load operation from the Modbus register.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Modbus address for PZD7 (PPO Read). A value of 0 will disable the PZD7
(PPO input) load operation from the Modbus register.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Modbus address for PZD8 (PPO Read). A value of 0 will disable the PZD8
(PPO input) load operation from the Modbus register.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Modbus address for PZD9 (PPO Read). A value of 0 will disable the PZD9
(PPO input) load operation from the Modbus register.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Modbus address for PZD10 (PPO Read). A value of 0 will disable the PZD10
(PPO input) load operation from the Modbus register.
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
11.7 F: OPTIONS
Default
Ref.
(Range)
0
663
0
663
0
663
0
663
0
663
0
663
0
663
0
664
0
664
0
664
0
664
0
664
0
664
0
664
0
664
0
665
429