Digital Output Card Selection
Refer to "H2: DIGITAL OUTPUTS" for more information about the functions that output from the terminals when
F5-09 = 2 [DO-A3 Output Mode Selection = 8 CH Sel (F5-01 to F5-08)]. Use F5-01 to F5-08 to set the output
items.
No.
F5-01
F5-02
F5-03
F5-04
F5-05
F5-06
F5-07
F5-08
F5-01 Term.P1-PC Function Select
No.
Name
(Hex.)
F5-01
Term.P1-PC Function
Select
(0399)
F5-02 Term.P2-PC Function Select
No.
Name
(Hex.)
F5-02
Term.P2-PC Function
Select
(039A)
F5-03 Term.P3-PC Function Select
No.
Name
(Hex.)
F5-03
Term.P3-PC Function
Select
(039B)
F5-04 Term.P4-PC Function Select
No.
Name
(Hex.)
F5-04
Term.P4-PC Function
Select
(039C)
F5-05 Term.P5-PC Function Select
No.
Name
(Hex.)
F5-05
Term.P5-PC Function
Select
(039D)
F5-06 Term.P6-PC Function Select
No.
Name
(Hex.)
F5-06
Term.P6-PC Function
Select
(039E)
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Name
Term.P1-PC Function Select
Term.P2-PC Function Select
Term.P3-PC Function Select
Term.P4-PC Function Select
Term.P5-PC Function Select
Term.P6-PC Function Select
Term.M1-M2 Function Select
Term.M3-M4 Function Select
V/f
CL-V/f
OLV
CLV
Sets the function of terminal P1-PC on the DO-A3 option. Set F5-09 = 2 [DO-A3 Output Mode
Selection = 8 CH Sel (F5-01 to F5-08)] to enable this function.
V/f
CL-V/f
OLV
CLV
Sets the function of terminal P2-PC on the DO-A3 option. Set F5-09 = 2 [DO-A3 Output Mode
Selection = 8 CH Sel (F5-01 to F5-08)] to enable this function.
V/f
CL-V/f
OLV
CLV
Sets the function of terminal P3-PC on the DO-A3 option. Set F5-09 = 2 [DO-A3 Output Mode
Selection = 8 CH Sel (F5-01 to F5-08)] to enable this function.
V/f
CL-V/f
OLV
CLV
Sets the function of terminal P4-PC on the DO-A3 option. Set F5-09 = 2 [DO-A3 Output Mode
Selection = 8 CH Sel (F5-01 to F5-08)] to enable this function.
V/f
CL-V/f
OLV
CLV
Sets the function of terminal P5-PC on the DO-A3 option. Set F5-09 = 2 [DO-A3 Output Mode
Selection = 8 CH Sel (F5-01 to F5-08)] to enable this function.
V/f
CL-V/f
OLV
CLV
Sets the function of terminal P6-PC on the DO-A3 option. Set F5-09 = 2 [DO-A3 Output Mode
Selection = 8 CH Sel (F5-01 to F5-08)] to enable this function.
Setting Range
0 - 192
0 - 192
0 - 192
0 - 192
0 - 192
0 - 192
0 - 192
0 - 192
Description
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
12.6 F: OPTIONS
Default
5: @Run
7: Zero Speed
F: SpeedAgree1
13: FreqDetect 1
1: Drive Ready
B: @FreqOutput
0: Through Mode
0: Through Mode
Default
(Range)
5
(0 - 1A7)
Default
(Range)
7
(0 - 1A7)
Default
(Range)
F
(0 - 1A7)
Default
(Range)
13
(0 - 1A7)
Default
(Range)
1
(0 - 1A7)
Default
(Range)
B
(0 - 1A7)
645