11.6 E: MOTOR

E2: MOTOR 1 PARAMETERS

No.
Name
(Hex.)
E2-01
Mot Rated Current
(FLA)
(030E)
E2-02
Mot Rated Slip
(030F)
E2-03
Mot No-Load Current
(0310)
E2-04
Motor Pole Count
(0311)
E2-05
Motor L-L Resistance
(0312)
E2-06
Motor Leak Inductance
(0313)
E2-07
Mot Sat Coeff 1
(0314)
E2-08
Mot Sat Coeff 2
(0315)
E2-09
Motor Mech Loss
(0316)
Expert
E2-10
Motor Iron Loss
(0317)
E2-11
Motor Rated Power
(kW)
(0318)

E3: V/F PARAMETER MOTOR 2

No.
Name
(Hex.)
E3-01
M2 Control Method
Selection
(0319)
E3-04
M2 Max Out Frequency
(031A)
E3-05
M2 Max Out Voltage
(031B)
E3-06
M2 Base Frequency
(031C)
E3-07
M2 Mid A Frequency
(031D)
E3-08
M2 Mid A Voltage
(031E)
E3-09
M2 Min Out Frequency
(031F)
416
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor rated current in amps.
V/f
CL-V/f
OLV
CLV
AOLV
Sets motor rated slip.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the no-load current for the motor in amps when operating at the rated frequency
and the no-load voltage.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of motor poles.
Note:
• When A1-02 = 0, 1, 3 [Control Method = V/f Control, PG V/f Control, CLVector],
the maximum value is 120.
• When A1-02 = 2, 4 [OLVector, Adv OLVector], the maximum value is 48.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the line-to-line resistance for the motor stator windings.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the voltage drop from motor leakage inductance when the motor is operating at the
rated frequency and rated current. This value is a percentage of Motor Rated Voltage.
V/f
CL-V/f
OLV
CLV
AOLV
Set the motor iron-core saturation coefficient when the magnetic flux is 50%.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor iron-core saturation coefficient at 75% of the magnetic flux.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the mechanical loss of the motor. Motor rated power (kw) = 100.0%. Usually it is
not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor iron loss.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor rated output in 0.01 kW increments.
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the control method for motor 2.
Note:
When you change this setting, the drive will set all parameters that are dependent on
this parameter to their default settings.
0 : V/f Control
1 : PG V/f Control
2 : OLVector
3 : CLVector
V/f
CL-V/f
OLV
CLV
AOLV
Set the maximum output frequency for the motor 2 V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the maximum output voltage for the motor 2 V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the base frequency for the motor 2 V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a middle output frequency for the motor 2 V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a middle output voltage for the motor 2 V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum output frequency for the motor 2 V/f pattern.
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Default
Ref.
(Range)
Determined by o2-04
617
and C6-01
(10% to 200% of the
drive rated current)
Determined by o2-04,
617
C6-01
(0.000 - 20.000 Hz)
Determined by o2-04
617
and C6-01
(0 to E2-01)
4
617
(2 - 120)
Determined by o2-04
618
and C6-01
(0.000 - 65.000 Ω)
Determined by o2-04
618
and C6-01
(0.0 - 60.0%)
0.50
618
(0.00 - 0.50)
0.75
618
(E2-07 - 0.75)
0.0%
618
(0.0 - 10.0%)
Determined by o2-04
619
and C6-01
(0 - 65535 W)
Determined by o2-04,
619
C6-01
(0.00 - 650.00)
Default
Ref.
(Range)
0
619
(0 - 3)
Determined by E3-01
620
(40.0 - 590.0 Hz)
Determined by E3-01
620
(400 V Class: 0.0 - 510.0
V)
Determined by E3-01
620
(0.0 - E3-04)
Determined by E3-01
620
(0.0 - E3-04)
Determined by E3-01
620
(400 V Class: 0.0 - 510.0
V)
Determined by E3-01
620
(0.0 - E3-04)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents