E5: Pm Motor Settings - Omron Q2A Series Technical Manual

Driving quality 400 v class 0.55 kw to 315 kw
Hide thumbs Also See for Q2A Series:
Table of Contents

Advertisement

E4-07 M2 Satur Coeff 1
No.
Name
(Hex.)
E4-07
M2 Satur Coeff 1
(0343)
The drive sets this parameter during Rotational Auto-Tuning. The drive uses this coefficient when it operates with
constant output.
E4-08 M2 Satur Coeff 2
No.
Name
(Hex.)
E4-08
M2 Satur Coeff 2
(0344)
The drive sets this parameter during Rotational Auto-Tuning. The drive uses this value to operate the motor at
constant output.
E4-09 M2 Mech Loss
No.
Name
(Hex.)
E4-09
M2 Mech Loss
(033F)
Expert
Adjust this parameter in these conditions. The drive adds the configured mechanical loss to the torque reference
value as a torque compensation value:
• There is a large quantity of torque loss from motor bearing friction.
• There is a large quantity of torque loss in fans and pumps.
E4-10 M2 Iron Loss
No.
Name
(Hex.)
E4-10
M2 Iron Loss
(0340)
E4-11 M2 Rated Power (kW)
No.
Name
(Hex.)
E4-11
M2 Rated Power (kW)
(0327)
Auto-Tuning automatically sets this parameter to the value input for [Motor Rated Power].
Note:
When the maximum applicable motor output < 300 kW, the drive uses 0.01 kW units. When the maximum applicable motor output >
300 kW, the drive uses 0.1 kW units.
The maximum applicable motor output changes when the value for C6-01 [ND/HD Duty Selection] changes.

E5: PM MOTOR SETTINGS

E5 parameters are used to set PM motor data.
Set E5-01 to the motor code when using PM motors recommended by the manufacturer. E5 and other related
motor parameters will be automatically set to the optimal values.
Perform Auto-Tuning for all other PM motors. If information from motor nameplates or test reports is available,
the E5 parameters can be manually entered.
Note:
• The keypad displays E5-xx only when A1-02 = 5, 6, 7 [Control Method = PM OLVector, PM AOLVector, PM CLVector].
• E5-xx parameters are not reset when the drive is initialized using parameter A1-03 [Init Parameters].
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor 2 iron-core saturation coefficient at 50% of the magnetic flux.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor 2 iron-core saturation coefficient at 75% of the magnetic flux.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the mechanical loss of motor 2. Motor rated power (kW) is 100%. Usually it is not necessary
to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor iron loss for motor 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor 2 rated power in 0.01 kW increments (1 HP = 0.746 kW).
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
12.5 E: MOTOR
Default
(Range)
0.50
(0.00 - 0.50)
Default
(Range)
0.75
(E4-07 - 0.75)
Default
(Range)
0.0%
(0.0 - 10.0%)
Default
(Range)
Determined by o2-04 and
C6-01
(0 - 65535 W)
Default
(Range)
Determined by o2-04 and
C6-01
(0.00 - 650.00 kW)
12
623

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents