Omron Q2A Series Technical Manual page 57

Driving quality 400 v class 0.55 kw to 315 kw
Hide thumbs Also See for Q2A Series:
Table of Contents

Advertisement

Attach the Conduit Bracket
1.
Align the screw holes on the stay bracket with the screw holes on the base. Tighten the included screws to
a tightening torque of 0.98 N∙m to 1.33 N∙m (8.67 lb.∙in. to 11.77 lb.∙in.) to attach the stay bracket to the
base.
A - Bracket
B - Base
2.
Align the screw holes on conduit bracket 1 with the screw holes on the drive and push the bracket into
position.
• Use the screws to attach the bracket.
• Tighten the screws to a correct tightening torque.
– Screw A: 0.98 N∙m to 1.33 N∙m (8.67 lb.∙in. to 11.77 lb.∙in.)
– Screw B: 1.96 N∙m to 2.53 N∙m (17.35 lb.∙in. to 22.39 lb.∙in.)
A - Screw holes on sides
B - Conduit bracket 1
Figure 2.64
shows the locations of the screw holes on the bottom of the drive.
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
C - Screws
Figure 2.62 Assemble Conduit Bracket 1
C - Screws A
D - Screws B
Figure 2.63 Attach Conduit Bracket 1