Omron Q2A Series Technical Manual page 567

Driving quality 400 v class 0.55 kw to 315 kw
Hide thumbs Also See for Q2A Series:
Table of Contents

Advertisement

C1-07 Accel Time 4
No.
Name
(Hex.)
C1-07
Accel Time 4
(0206)
RUN
Note:
When C1-10 = 0 [Ac/Dec Units = 0.01s], the setting range is 0.00 to 600.00 s.
C1-08 Decel Time 4
No.
Name
(Hex.)
C1-08
Decel Time 4
(0207)
RUN
Note:
When C1-10 = 0 [Ac/Dec Units = 0.01s], the setting range is 0.00 to 600.00 s.
C1-09 Fast Stop Time
No.
Name
(Hex.)
C1-09
Fast Stop Time
(0208)
Note:
• When C1-10 = 0 [Ac/Dec Units = 0.01s], the setting range is 0.00 to 600.00 s.
• When L2-29 = 1 [KEB Method = Single KEB1 Ride-Thru] and you do KEB Auto-Tuning, the drive will automatically set C1-09. If
you must not change the Fast Stop time, do not do KEB Auto-Tuning.
The Fast Stop function will be triggered in the following circumstances.
• The Fast Stop operation will be triggered by the input of the Fast Stop command via the multi-function digital
input terminal.
• The Fast Stop operation is will be triggered when by the input of the Fast Stop command is input via the multi-
function digital input terminal.
Set H1-xx = 34, 35 [MFDI Function Select = Fast Stop (NO), Fast Stop (NC)].
When the Fast Stop command is input, the Fast Stop operation will be triggered at the deceleration time set to C1-
09. The drive cannot be restarted after initiating a Fast Stop operation until deceleration is complete. Complete
deceleration and cycle the Run command to clear the Fast Stop input.
The terminal set for H2-xx = 17 [MFDO Function Select = @Fast Stop] will be ON during Fast Stop.
Note:
Decelerating too quickly can cause an ov [Overvoltage] fault that shuts off the drive while the motor to coasts to a stop. Set a Fast Stop
time in C1-09 that prevents motor coasting and makes sure that the motor stops quickly and safely.
C1-10 Ac/Dec Units
No.
Name
(Hex.)
C1-10
Ac/Dec Units
(0209)
0 : 0.01s
Sets acceleration and deceleration times in 0.01 s units. The setting range is 0.0 to 6000.0 s.
If one of these parameters is set to 1000.0 s or longer, you cannot set C1-10 = 0:
• C1-01 to C1-09
• L2-06
• L2-07
When one of those parameters is set to a value between 600.1 s and 1000.0 s, you can set C1-10 = 0, but the time
will change to 600.00 s.
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Sets the length of time to accelerate from zero to maximum output frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the length of time to decelerate from maximum output frequency to zero.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the length of time that the drive will decelerate to zero for a Fast Stop.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the setting units for C1-01 to C1-08 [Accel/Decel Times 1 to 4], C1-09 [Fast Stop Time], L2-
06 [KEB Decel Time], and L2-07 [KEB Accel Time].
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
12.3 C: TUNING
Default
(Range)
10.0 s
(0.0 - 6000.0 s)
Default
(Range)
10.0 s
(0.0 - 6000.0 s)
Default
(Range)
10.0 s
(0.0 - 6000.0 s)
Default
(Range)
1
(0, 1)
12
567