Omron Q2A Series Technical Manual page 798

Driving quality 400 v class 0.55 kw to 315 kw
Hide thumbs Also See for Q2A Series:
Table of Contents

Advertisement

12.9 n: SPECIAL
n8-11 Observ.Calc Gain2
No.
Name
(Hex.)
n8-11
Observ.Calc Gain2
(054A)
Note:
When n8-72 = 1 [Spd Obs. Method Selection = Method 1], the default value is 50.0. When n8-72 = 2 [Method 2], the default value is
30.0 for drives that have a maximum capacity of 4023. The default is 50.0 for 4031 and larger models.
n8-14 Polar Comp Gain3
No.
Name
(Hex.)
n8-14
Polar Comp Gain3
(054D)
Expert
n8-15 Polar Comp Gain4
No.
Name
(Hex.)
n8-15
Polar Comp Gain4
(054E)
Expert
n8-21 Mot Back-EMF (Ke) Gain
No.
Name
(Hex.)
n8-21
Mot Back-EMF (Ke) Gain
(0554)
Expert
n8-35 InitRotorPos Selection
No.
Name
(Hex.)
n8-35
InitRotorPos Selection
(0562)
When A1-02 = 7 [Control Method = PM CLVector], the initial motor magnetic pole detection operates the first
time after the drive is energized. After that, the drive uses the encoder signal to calculate the rotor position and the
drive saves the value until the drive is de-energized.
1 : Pull-In
Starts the rotor with pull-in current.
2 : HiFreq Injection
Injects high frequency to detect the rotor position. This setting can cause a loud excitation sound when the motor
starts.
3 : Pulse Injection
Inputs the pulse signal to the motor to detect the rotor position.
Note:
• When you use an SPM motor, set this parameter to 1. Values between 1 to 3 can be selected if using IPM motors.
• If the drive incorrectly detects the polarity direction, the motor can rotate in the opposite direction of the Run command.
n8-36 HFI Signal Frequency
No.
Name
(Hex.)
n8-36
HFI Signal Frequency
(0563)
PM Rotational Auto-Tuning and PM Stationary Auto-Tuning automatically calculate this parameter value.
798
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain for speed estimation. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain for speed estimation. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain for speed estimation. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain for speed estimation. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets how the drive detects the position of the rotor at start.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the injection frequency for high frequency injection.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Default
(Range)
Determined by n8-72
(0.0 - 1000.0)
Default
(Range)
2.000
(0.000 - 20.000)
Default
(Range)
2.000
(0.000 - 20.000)
Default
(Range)
0.90
(0.80 - 1.00)
Default
(Range)
Determined by A1-02
(1 - 3)
Default
(Range)
500 Hz
(200 - 5000 Hz)