Omron Q2A Series Technical Manual page 701

Driving quality 400 v class 0.55 kw to 315 kw
Hide thumbs Also See for Q2A Series:
Table of Contents

Advertisement

OFF : Safety circuit fault or RUN/READY
Terminal H1-HC or terminal H2-HC is OFF or released (safety circuit fault), or the two terminals are ON or have
short circuited (RUN/READY).
F: SpeedAgree1
Setting
Function
F
SpeedAgree1
Note:
• The motor rotation direction does not have an effect on the detection function.
• CLV control uses motor speed as the reference.
ON : The output frequency is in the range of "frequency reference ± L4-02."
OFF : The output frequency does not align with the frequency reference although the drive is
running.
10: USpeedAgree1
Setting
Function
10
USpeedAgree1
Note:
• The motor rotation direction does not have an effect on the detection function. The drive uses the L4-01 value as the forward/reverse
detection level.
• CLV control uses motor speed as the reference.
ON : The output frequency is in the range of "L4-01 ± L4-02" and the range of frequency
reference ± L4-02.
OFF : The output frequency is not in the range of "L4-01 ± L4-02" or the in the range of frequency
reference ± L4-02.
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
The terminal turns on when the output frequency is in the range of the frequency reference ± L4-02 [SpAgree Det.Width].
Figure 12.88 Speed Agree 1 Time Chart
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the output frequency is in the range of L4-01 [SpAgree Det.Level] ± L4-02 [SpAgree Det.Width]
and in the range of the frequency reference ± L4-02.
Figure 12.89 User-Defined Speed Agree 1 Time Chart
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM