C3: SLIP COMPENSATION

No.
Name
(Hex.)
C3-01
Slip Comp Gain
(020F)
RUN
C3-02
Slip Comp Delay Time
(0210)
RUN
C3-03
Slip Comp Limit
(0211)
C3-04
Slip Comp@Regen
(0212)
C3-05
Vout Limit Selection
(0213)
C3-16
Vout Limit Start Level
(0261)
Expert
C3-17
Vout Limit Max Level
(0262)
Expert
C3-18
Vout Limit Level
(0263)
Expert
C3-21
M2 Slip Comp Gain
(033E)
RUN
C3-22
M2 Slip Comp
DelayTime
(0241)
RUN
C3-23
M2 Slip Comp Limit
(0242)
C3-24
M2 Slip Comp Regen
Condition
(0243)
C3-28
Adaptative Slip Control
Mode
(1B5B)
Expert
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain for the slip compensation function. Usually it is not necessary to change
this setting.
Note:
Correctly set these parameters before changing the slip compensation gain:
• E2-01 [Mot Rated Current (FLA)]
• E2-02 [Mot Rated Slip] (Set during Auto-Tuning when A1-02 = 2 [Control
Method = OLVector])
• E2-03 [Mot No-Load Current]
V/f
CL-V/f
OLV
CLV
AOLV
Sets the slip compensation delay time when speed is unstable or when the slip
compensation response is too slow. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the upper limit for the slip compensation function as a percentage of the motor
rated slip.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the slip compensation function during regenerative operation.
0 : Disabled
1 : Enable>6 Hz
2 : Enable>C3-15
V/f
CL-V/f
OLV
CLV
AOLV
Sets the automatic reduction of motor magnetic flux when the output voltage is
saturated.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the modulation factor that starts the output voltage limit operation when C3-05 = 1
[Vout Limit Selection = Enabled].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the modulation factor used with C3-18 [Vout Limit Level] for the output voltage
limit operation when C3-05 = 1 [Vout Limit Selection = Enabled].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the maximum drop width of the voltage reference when C3-05 = 1 [Vout Limit
Selection = Enabled].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain for the motor 2 slip compensation function. Usually it is not necessary to
change this setting.
Note:
Correctly set these parameters before changing the slip compensation gain:
• E4-01 [M2 Rated Current (FLA)]
• E4-02 [M2 Rated Slip] (Set during Auto-Tuning when E3-01 = 2 [M2 Control
Method Selection = OLVector])
• E4-03 [M2 No-Load Current]
V/f
CL-V/f
OLV
CLV
AOLV
Sets the slip compensation delay time for motor 2 when speed is unstable or when the
slip compensation response is too slow. Usually it is not necessary to change this
setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the upper limit for the slip compensation function as a percentage of the motor 2
rated slip.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the slip compensation during regenerative operation function for motor 2.
0 : Disabled
1 : Enable>6 Hz
2 : Enable>C3-15
V/f
CL-V/f
OLV
CLV
AOLV
Sets the slip compensation function mode.
0 : Normal
1 : Advanced
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
11.4 C: TUNING
Default
Ref.
(Range)
Determined by A1-02
570
(0.0 - 2.5)
Determined by A1-02
571
(0 - 10000 ms)
200%
571
(0 - 250%)
0
571
(0 - 2)
0
572
(0, 1)
90.0%
572
(70.0 - 90.0%)
100.0%
572
(85.0 - 100.0%)
90.0%
572
(50.0 - 100.0%)
Determined by E3-01
572
(0.0 - 2.5)
Determined by E3-01
573
(0 - 10000 ms)
200%
573
(0 - 250%)
0
573
(0 - 2)
0
574
(0, 1)
407
11