12.7 H: TERMINALS
H2-31 Compare2 Off-Delay Time
No.
Name
(Hex.)
H2-31
Compare2 Off-Delay Time
(154B)
Note:
Refer to H2-xx = 66 and 67 [MFDO Function Select = Comparator1 and Comparator2] for more information about the comparator
function.
H2-32 Compare1 Filter Time
No.
Name
(Hex.)
H2-32
Compare1 Filter Time
(159A)
H2-33 Compare1 Protection Selection
No.
Name
(Hex.)
H2-33
Compare1 Protection
Selection
(159B)
0 : Ramp->Stop
The drive ramps to stop in the set deceleration time. Fault relay output terminal 1NO-1CM activates and terminal
1NC-1CM deactivates.
1 : Coast->Stop
The drive output shuts off and the motor coasts to stop. Fault relay output terminal 1NO-1CM activates and
terminal 1NC-1CM deactivates.
2 : Fast Stop (C1-09)
The drive stops the motor in the deceleration time set in C1-09 [Fast Stop Time]. Fault relay output terminal 1NO-
1CM activates and terminal 1NC-1CM deactivates.
3 : Alarm Only
The keypad shows "CP1" and the drive continues operation at the current frequency reference.
Note:
The output terminal set for Alarm [H2-01 to H2-03 = 10] activates.
4 : Low Speed (L8-19)
H2-34 Compare2 Filter Time
No.
Name
(Hex.)
H2-34
Compare2 Filter Time
(159C)
H2-35 Compare2 Protection Selection
No.
Name
(Hex.)
H2-35
Compare2 Protection
Selection
(159D)
0 : Ramp->Stop
The drive ramps to stop in the set deceleration time. Fault relay output terminal 1NO-1CM activates and terminal
1NC-1CM deactivates.
1 : Coast->Stop
The drive output shuts off and the motor coasts to stop. Fault relay output terminal 1NO-1CM activates and
terminal 1NC-1CM deactivates.
2 : Fast Stop (C1-09)
694
V/f
CL-V/f
OLV
CLV
AOLV
Sets the off-delay time for comparator 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time constant that is applied to the primary delay filter used for the analog output of the
monitor selected with H2-20 [Compare1 Mon.Selection].
V/f
CL-V/f
OLV
CLV
AOLV
Sets drive operation when it detects CP1 [Comparator1 Limit Fault].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time constant that is applied to the primary delay filter used for the analog output of the
monitor selected with H2-26 [Compare2 Mon.Selection].
V/f
CL-V/f
OLV
CLV
AOLV
Sets drive operation when it detects CP2 [Comparator2 Limit Fault].
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Default
(Range)
0.0 s
(0.0 - 600.0 s)
Default
(Range)
0.0s
(0.0 - 10.0 s)
Default
(Range)
4
(0 - 4)
Default
(Range)
0.0s
(0.0 - 10.0 s)
Default
(Range)
4
(0 - 4)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents