Open Loop Vector Control Method - Omron Q2A Series Technical Manual

Driving quality 400 v class 0.55 kw to 315 kw
Hide thumbs Also See for Q2A Series:
Table of Contents

Advertisement

Model
2 kHz
5 kHz
8.6
7.9
4009
9.8
8.9
4012
4018
14.1
12.9
18.0
16.4
4023
27.2
24.7
4031
34.7
31.6
4038
34.0
34.0
4044
40.0
40.0
4060
52.0
52.0
4075
4089
65.0
65.0
77.0
77.0
4103
96.0
96.0
4140
124.0
124.0
4168
4208
156.0
156.0
180.0
180.0
4250
240.0
240.0
4296
302.0
302.0
4371
4389
361.0
361.0
414.0
345.0
4453
477.0
397.5
4568
-
-
4675
Carrier Frequency Settings and Rated Current Values when Using PM
Advanced Open Loop Vector Control Method
The following tables show how the drive rated output current changes when C1-02 [Decel Time 1] value changes,
and when A1-02 = 6 [Control Method = PM AOLVector]. The output current value changes linearly as the carrier
frequency changes. You can use the values from the tables to calculate a frequency that is not shown.
400 V Class
Table 10.12 AOLV/PM Carrier Frequency and Rated Current Derating (< 460 V)
Model
2 kHz
4 kHz
1.8
1.8
4002
3.4
3.4
4004
4005
4.8
4.8
5.5
5.5
4007
7.2
7.2
4009
9.2
9.2
4012
14.8
14.8
4018
18.0
18.0
4023
24.0
24.0
4031
4038
31.0
31.0
39.0
39.0
4044
45.0
45.0
4060
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Heavy Duty Rating (HD2)
8 kHz
10 kHz
12.5 kHz
6.9
6.2
5.4
7.6
6.7
5.6
11.0
9.7
8.2
14.0
12.4
10.4
21.0
18.5
15.4
27.0
23.9
20.1
34.0
30.1
25.3
40.0
34.8
28.3
52.0
46.1
38.6
65.0
57.6
48.3
77.0
68.2
57.2
78.7
67.2
-
101.7
86.8
-
127.9
109.2
-
147.6
126.0
-
196.8
168.0
-
247.6
211.4
-
296.0
252.7
-
-
-
-
-
-
-
-
-
-
Heavy Duty Rating (HD1)
6 kHz
8 kHz
10 kHz
1.7
1.3
1.0
3.2
2.4
1.7
4.5
3.8
3.0
5.2
4.2
3.2
6.9
5.8
4.8
8.7
7.0
5.4
14.0
11.4
8.9
17.0
13.9
10.8
22.6
18.4
14.1
29.2
23.9
18.6
36.8
30.1
23.4
42.1
33.3
24.4
Rated Current (A)
Normal Duty Rating (ND2)
15 kHz
2 kHz
5 kHz
4.6
7.6
7.0
4.5
11.0
10.0
6.6
15.2
13.9
8.4
21
19.3
12.4
27
24.5
16.2
34
32.5
20.4
40
39.6
21.7
52
46.9
31.2
65
64.1
39.0
77
76.6
46.2
96
96.0
-
124
108.7
-
156
139.8
-
180
155.5
-
240
212.9
-
302
268.8
-
361
318.5
-
414
370
-
477
367
-
515
397
-
-
-
Rated Current (A)
Normal Duty Rating (ND1)
12 kHz
2 kHz
4 kHz
0.6
2.1
1.9
1.0
4.1
3.7
2.3
5.4
5.0
2.3
7.1
6.1
3.8
8.9
7.9
3.8
11.9
10.3
6.3
17.5
16.5
7.7
23.4
20.4
9.9
31.0
26.8
13.3
38.0
34.5
16.7
44.0
41.6
15.6
59.6
50.8
10.4 Drive Derating
8 kHz
10 kHz
12.5 kHz
6.1
5.5
4.8
8.5
7.5
6.2
11.8
10.5
8.8
16.4
14.6
12.2
20.9
18.4
15.4
27.7
24.6
20.6
34.1
30.5
25.9
39.2
34.1
27.7
54.6
48.3
40.4
65.5
58.0
48.7
84.1
74.6
62.8
85.7
70
-
115.5
99
-
118.7
94
-
172.3
145
-
218.9
186
-
254.7
212
-
303.3
259
-
-
-
-
-
-
-
-
-
-
6 kHz
8 kHz
10 kHz
1.7
1.6
1.4
3.3
2.8
2.4
4.7
4.3
3.9
5.2
4.2
3.2
6.8
5.8
4.8
8.6
7.0
5.4
14.0
11.4
8.9
17.3
14.1
11.0
22.6
18.3
14.1
29.2
23.9
18.6
35.5
29.5
23.4
42.0
33.2
24.4
15 kHz
4.1
5.0
7.1
9.9
12.3
16.6
21.3
21
33
39
51
-
-
-
-
-
-
-
-
-
-
12 kHz
1.2
2.0
3.6
2.3
3.7
3.8
10
6.3
7.8
9.9
13.3
17.3
15.6
361

Hide quick links:

Advertisement

Table of Contents
loading