12.7 H: TERMINALS
11: SpeedAgree2
Setting
Function
11
SpeedAgree2
Note:
• The motor rotation direction does not have an effect on the detection function. The drive uses the L4-01 value as the forward/reverse
detection level.
• CLV and CLV/PM control use motor speed as the reference.
ON : The output frequency is in the range of "frequency reference ± L4-04".
OFF : The output frequency is not in the range of "frequency reference ± L4-04".
12: USpeedAgree2
Setting
Function
12
USpeedAgree2
Note:
• The detection level configured with L4-03 is a signed value. The drive will only detect in one direction.
• CLV and CLV/PM control use motor speed as the reference.
ON : The output frequency is in the range of "L4-03 ± L4-04" and the range of frequency
reference ± L4-04.
OFF : The output frequency is not in the range of "L4-03 ± L4-04" or the in the range of frequency
reference ± L4-04.
702
V/f
CL-V/f
OLV
The terminal activates when the output frequency is in the range of the frequency reference ± L4-04 [SpAgree Det.Width(+/-)].
Figure 12.90 Speed Agree 2 Time Chart
V/f
CL-V/f
OLV
The terminal activates when the output frequency is in the range of L4-03 [SpAgree Det.Level(+/-)] ± L4-04 [SpAgree Det.
Width(+/-)] and in the range of the frequency reference ± L4-04.
Figure 12.91 Example of User-set Speed Agree 2 (L4-03 Is Positive)
Description
CLV
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
CLV
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual