Omron Q2A Series Technical Manual page 635

Driving quality 400 v class 0.55 kw to 315 kw
Hide thumbs Also See for Q2A Series:
Table of Contents

Advertisement

Note:
For a single-pulse encoder, the dividing ratio for the monitor signal is 1:1.
F1-36 Enc2 PCB Disconnect Detect
No.
Name
(Hex.)
F1-36
Enc2 PCB Disconnect
Detect
(03B5)
0 : Disabled
1 : Enabled
F1-37 Enc2 Signal Selection
No.
Name
(Hex.)
F1-37
Enc2 Signal Selection
(03BD)
0 : A Pulse Detection
1 : AB Pulse Detection
F1-50 Enc Selection
No.
Name
(Hex.)
F1-50
Enc Selection
(03D2)
0 : EnDat Sin/Cos
1 : EnDat Serial Only
2 : Hiperface
F1-51 PGoH Detect Level
No.
Name
(Hex.)
F1-51
PGoH Detect Level
(03D3)
The drive will detect PGoH when the value of this parameter is less than the value of
For expression
single-track (phase A) output from the encoder.
Note:
This function is enabled when F1-20 = 1 [Enc1 PCB Disconnect Detect = Enabled].
F1-52 Serial Enc bps for Communication
No.
Name
(Hex.)
F1-52
Serial Enc bps for
Communication
(03D4)
Note:
Set F1-50 = 1 or 2 [Enc Selection = EnDat Serial Only or Hiperface] to enable this function.
0 : 1M/9600bps
1 : 500k/19200bps
2 : 1M/38400bps
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that enables and disables detection of a disconnected encoder connection cable
to cause PGoH [Encoder (PG) Hardware Fault] for motor 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of channels for the signal to the encoder option card for motor 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the type of encoder connected to the PG-F3 option.
V/f
CL-V/f
OLV
CLV
AOLV
The drive will detect PGoH [Encoder (PG) Hardware Fault] when the value of this parameter is
less than the value of
, Sin θ is the single-track (phase B) output from the encoder and Cos θ is the
V/f
CL-V/f
OLV
CLV
AOLV
Sets the communication speed between the PG-F3 option and the serial encoder.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
12.6 F: OPTIONS
Default
(Range)
1
(0, 1)
Default
(Range)
0
(0, 1)
Default
(Range)
0
(0 - 2)
Default
(Range)
80%
(1 - 100%)
.
Default
(Range)
0
(0 - 2)
12
635

Hide quick links: