Omron Q2A Series Technical Manual page 679

Driving quality 400 v class 0.55 kw to 315 kw
Hide thumbs Also See for Q2A Series:
Table of Contents

Advertisement

3E: SCBraking NO
Setting
Function
3E
SCBraking NO
If a three-phase PM motor short circuits, the drive will generate braking torque in the spinning motor. This will
stop motor rotation and also prevent external forces from spinning the motor.
Note:
• When A1-02 = 8 [Control Method = EZ Vector], this function is available if you use a PM motor.
• Refer to "b2: DC INJ / SHORT CKT BRAKE" for more information.
ON : Short Circuit Braking is enabled.
OFF : Normal operation
3F: SCBraking NC
Setting
Function
3F
SCBraking NC
If a three-phase PM motor short circuits, the drive will generate braking torque in the spinning motor. This will
stop motor rotation and also prevent external forces from spinning the motor.
Note:
• When A1-02 = 8 [Control Method = EZ Vector], this function is available if you use a PM motor.
• Refer to "b2: DC INJ / SHORT CKT BRAKE" for more information.
ON : Normal operation
OFF : Short Circuit Braking is enabled.
40: KEB Thru1 NC
Setting
Function
40
KEB Thru1 NC
ON : Normal operation
OFF : Deceleration during momentary power loss
When you enable KEB Ride-Thru 1, set L2-29 [KEB Method]. The drive operates with the selected KEB method.
Note:
• If you set KEB Ride-Thru 1 [H1-xx = 40, 41] and KEB Ride-Thru 2 [H1-xx = 42, 43] at the same time, the drive will detect oPE03
[Multi-Function Input Setting Err].
• Refer to "KEB Ride-Thru function" for more information.
41: KEB Thru1 NO
Setting
Function
41
KEB Thru1 NO
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Figure 12.79 Fast Stop Time Chart
V/f
CL-V/f
OLV
CLV
AOLV
Sets operation of Short Circuit Braking (N.O.).
V/f
CL-V/f
OLV
CLV
AOLV
Sets operation of Short Circuit Braking (N.C.).
V/f
CL-V/f
OLV
CLV
AOLV
Sets operation of the KEB1 function through the KEB Ride-Thru 1 (N.C.).
V/f
CL-V/f
OLV
CLV
AOLV
Sets operation of the KEB1 function through the KEB Ride-Thru 1 (N.O.).
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
12.7 H: TERMINALS
679
12

Hide quick links: