Note:
If F6-52 [DNet PCA Setting] and F6-53 [DNet PPA Setting] are not correct, the value is reset to default.
F6-54 DNet Idle Fault Detection
No.
Name
(Hex.)
F6-54
DNet Idle Fault Detection
(03C5)
0 : Enabled
1 : Disabled, No Fault Detection
Does not detect EF0 issues.
2 : Vendor Specific
3 : RUN Forward
4 : RUN Reverse
F6-55 DNet Baud Monitor
No.
Name
(Hex.)
F6-55
DNet Baud Monitor
(03C6)
0 : 125 kbps
1 : 250 kbps
2 : 500 kbps
F6-56 DNet Speed Scale Factor
No.
Name
(Hex.)
F6-56
DNet Speed Scale Factor
(03D7)
F6-57 DNet Current Scale Factor
No.
Name
(Hex.)
F6-57
DNet Current Scale Factor
(03D8)
F6-58 DNet Torque Scale Factor
No.
Name
(Hex.)
F6-58
DNet Torque Scale Factor
(03D9)
F6-59 DNet Power Scaling
No.
Name
(Hex.)
F6-59
DNet Power Scaling
(03DA)
F6-60 DNet Voltage Scale
No.
Name
(Hex.)
F6-60
DNet Voltage Scale
(03DB)
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to detect EF0 [Option Card External Fault] when the drive does not receive
data from the DeviceNet master.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to see the actual DeviceNet communications speed using the keypad. This
parameter functions as a monitor only.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the speed scale for DeviceNet communication.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the current scale of the DeviceNet communication master.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the torque scale of the DeviceNet communication master.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the power scale of the DeviceNet communication master.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the voltage scale of the DeviceNet communication master.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
12.6 F: OPTIONS
Default
(Range)
0
(0 - 4)
Default
(Range)
0
(0 - 2)
Default
(Range)
0
(-15 - +15)
Default
(Range)
0
(-15 - +15)
Default
(Range)
0
(-15 - +15)
Default
(Range)
0
(-15 - +15)
Default
(Range)
12
0
(-15 - +15)