Omron Q2A Series Technical Manual page 828

Driving quality 400 v class 0.55 kw to 315 kw
Hide thumbs Also See for Q2A Series:
Table of Contents

Advertisement

12.11 T: AUTOTUNING
1 : SPM Motor
T2-04 PMMot Rated Power
No.
Name
(Hex.)
T2-04
PMMot Rated Power
(0730)
Note:
Capacities 300 kW and less are set in units of 0.01 kW. Capacities above 300 kW are set in units of 0.1 kW. The maximum applicable
motor output varies depending on the setting of C6-01 [ND/HD Duty Selection].
T2-05 PMMot Rated Voltage
No.
Name
(Hex.)
T2-05
PMMot Rated Voltage
(0732)
T2-06 PMMot Rated Current
No.
Name
(Hex.)
T2-06
PMMot Rated Current
(0733)
T2-07 PMMot Base Frequency
No.
Name
(Hex.)
T2-07
PMMot Base Frequency
(0753)
T2-08 PMMot Poles Number
No.
Name
(Hex.)
T2-08
PMMot Poles Number
(0734)
T2-09 PMMot Base Speed
No.
Name
(Hex.)
T2-09
PMMot Base Speed
(0731)
T2-10 PMMot Stator Resistance
No.
Name
(Hex.)
T2-10
PMMot Stator Resistance
(0754)
Note:
This parameter does not set line-to-line resistance.
T2-11 PMMot dAxis Inductance
No.
Name
(Hex.)
T2-11
PMMot dAxis Inductance
(0735)
828
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rated output power (kW) of a PM motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rated voltage (V) of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rated current (A) of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the base frequency (Hz) of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of motor poles.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor base speed (min
-1
(r/min)).
V/f
CL-V/f
OLV
CLV
AOLV
Sets the stator resistance for each motor phase.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the d-axis inductance of the motor on a per phase basis.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Default
(Range)
Determined by o2-04 and
C6-01
(0.00 - 650.00 kW)
Default
(Range)
400 V Class: 400.0 V
(400 V Class: 0.0 - 510.0
V)
Default
(Range)
Determined by o2-04
(10% to 200% of the drive
rated current)
Default
(Range)
87.5 Hz
(0.0 - 590.0 Hz)
Default
(Range)
6
(2 - 48)
Default
(Range)
-1
1750 min
(r/min)
(0 - 34500 min
-1
(r/min))
Default
(Range)
Determined by T2-02
(0.000 - 65.000 Ω)
Default
(Range)
Determined by T2-02
(0.00 - 600.00 mH)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents