Omron E5AK-AA2-500 Manual

Omron E5AK-AA2-500 Manual

Digital process controller
Hide thumbs Also See for E5AK-AA2-500:

Advertisement

Digital Process Controller Series
Advanced Process Digital
Controllers
Field configurable output and option
boards
100 ms sampling (for analog input)
Advanced PID, or fuzzy self-tuning
Conforms to UL, CSA and CE standards
IP66/NEMA4X front panel
Remote set point (for E5EK and E5AK
only)
Set point ramp
Serial communications (RS-232C, and
RS-485; RS-422 for E5AK and E5EK
only) and transfer output (4 to 20 mA)
Front panel programming
Heat/cool or standard operation
Auto/manual and ON/OFF selections
Ordering Information
Order Control Output Boards and Option Boards separately below. Example: for a Relay Control Output, order the E53-R4R4 Output
Board in addition to the E5CK-AA1-500 Process Controller. For E5AK or E5EK, order an E53-R output module.
Note: You can mount only one Output Board and one Option Board to E5EK or E5CK.
Item
Standard models
Position--proportional
24 AC/DC models
Note: 1. When using the heater burnout alarm function with a standard model, the Linear Output Module cannot be used for the control
outputs (heat). The Digital Controller provides transfer outputs at 4 to 20 mA for the PV and other values and control outputs at
4 to 20 mA for the current outputs.
2. Order Output and Option Boards separately.
3. E5EK-PRR2/E5AK-PRR2 controllers are supplied with relay output. The relay output is not compatible with any other module.

Description
Base Unit with terminal cover
Base Unit with terminal cover
Base Unit with terminal cover
E5 K
Part number
E5AK-AA2-500
E5EK-AA2-500
E5CK-AA1-500
E5CK-AA1-302
E5AK-PRR2-500
E5EK-PRR2-500
E5AK-AA2-500 AC/DC 24V
E5AK-PRR2-500 AC/DC 24V
E5EK-AA2-500 AC/DC 24V
E5EK-PRR2-500 AC/DC 24V
E5CK-AA1-500 AC/DC 24V

Advertisement

Table of Contents
loading

Summary of Contents for Omron E5AK-AA2-500

  • Page 1 Base Unit with terminal cover E5AK-PRR2-500 E5EK-PRR2-500 24 AC/DC models Base Unit with terminal cover E5AK-AA2-500 AC/DC 24V E5AK-PRR2-500 AC/DC 24V E5EK-AA2-500 AC/DC 24V E5EK-PRR2-500 AC/DC 24V E5CK-AA1-500 AC/DC 24V Note: 1. When using the heater burnout alarm function with a standard model, the Linear Output Module cannot be used for the control outputs (heat).
  • Page 2 E5 K E5 K Ordering Information Table -- continued from previous page Item Description Part number Output Module (for E5AK and E5EK only) Relay E53-R E53-S Pulse (NPN) 12 VDC E53-Q Pulse (NPN) 24 VDC E53-Q3 Pulse (PNP) 24 VDC E53-Q4 Linear (4 to 20 mA) E53-C3...
  • Page 3 E5 K E5 K INPUT TYPES (SELECTABLE WITH INPUT JUMPER CONNECTOR) Platinum Resistance Thermometer (RTD’s) Input (field selectable) JPt100 Pt100 °C Range --199.9 to 650.0 --199.9 to 650.0 °F --199.9 to 999.9 --199.9 to 999.9 Input setting number Thermocouple Input (field selectable) (see note) °C...
  • Page 4: Specifications

    Remote SP input (for E5AK and E5EK only) Current input Current Transformer input (for E5AK and E5EK only) Connect only an Omron Current Transformer (E54-CT1 or E54-CT3) Other functions Standard Manual output, heating/cooling control, SP limiter, loop burnout alarm, SP...
  • Page 5 E5 K E5 K CHARACTERISTICS Indication accuracy (See Note.) Thermocouple: (±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max. Platinum resistance thermometer: (±0.2% of indication value or ±0.8°C, whichever is greater) ±1 digit max. Analog input: ±0.2% (of indication value) ±1 digit max. Hysteresis 0.01% to 99.99% FS (in units of 0.01% FS) Proportional band (P)
  • Page 6 E5 K E5 K OPTION BOARD RATINGS AND CHARACTERISTICS Event inputs Contact input: ON: 1 kΩ max., OFF: 100 kΩ min. No-contact input: ON: residual voltage 1.5 V max., OFF: leakage current 0.1 mA max. Communications Interface RS-232C and RS-485; RS-422 for E5AK and E5EK only Transmission Half-duplex method...
  • Page 7 E5 K E5 K Nomenclature E5AK Operation Indicators • OUT1 No. 1 display Lit when control output 1 turns ON. • OUT2 Operation No. 2 display Lit when control output 2 turns ON. Indicators • SUB1 Lit when the output function assigned to auxiliary output 1 turns ON.
  • Page 8: Operation

    E5 K E5 K Operation OPERATING PARAMETERS Mode Selection Press the Display Key for 1 sec. min. to switch to modes other than To Access Protect Mode the manual or protect mode. Press and hold the A/M Key and the Display Key for more than 1 second.
  • Page 9: Parameters Definitions

    E5 K E5 K PARAMETERS DEFINITIONS Refer to your User’s Manual for each parameter and the calibration mode in detail. Level 0 Mode for E5AK and E5EK PV/SV The process value is displayed on the No.1 display and the set point is displayed    on the No.2 display.
  • Page 10 E5 K E5 K Security Using the Security Level Table: Any mode marked with an X is displayed in the Security Level indicated.    Example: Selecting Security Level 2: Displays these modes: Level 0, Level 1 and Level 2 only. Does NOT display these modes: Setup, Expansion, Option, Calibration Mode Set value...
  • Page 11: Level 1 Mode

    E5 K E5 K Level 1 Mode AT Execute/Cancel Starts the Auto-tune function or cancels an active auto-tune. When an active auto-tune is cancelled, the original PID constants will be used again. AT-1 = Limited MV change during Autotuning (±40% max.) AT-2 = Full MV change during Autotuning (±100% max.) Note: E5AK and E5EK can have up to 4 set points or 4 alarms...
  • Page 12 E5 K E5 K Level 1 Valve Positioning Model (for E5AK and E5EK only) Position Proportional Dead Band For valve positioning units only. Used to adjust the dead band for a valve; displayed in percentage format. Range = 0.1--10 Default = 2.0 Heater Current Monitor Available when the heater burnout alarm is assigned.
  • Page 13: Level 2 Mode

    E5 K E5 K Level 2 Mode Remote/Local    Used for the communications function. Only accessible when communication option boards are installed. Determines whether the user will program the unit by the key pads on the face plate (local), by a comput- er, or PLC (remote).
  • Page 14: Setup Mode

    E5 K E5 K Setup Mode Input Type    Sets the input type connected to terminals 6 through 8. Note: Set input jumper to current, voltage, or temperature setting before changing input type. Default = 2 (K1 type thermocouple) Scaling Upper Limit    Used if the input type connected to the Controller is an analog input (voltage or current input).
  • Page 15: Close In Alarm/Open In Alarm

    E5 K E5 K Selecting a Control Method When selecting a control method, refer to the following table for correct parameter setting. Control method Control output 1 assignment Control output 2 assignment Operation Heat Control output (heat) Reverse Cool Control output (heat) Direct Heat/Cool Control output (heat)
  • Page 16: Expansion Mode

    E5 K E5 K Expansion Mode SP Setting Upper Limit    Stops the set point from going higher than the SP setting upper limit.  Default = 1300 This setting has no effect on the input scaling values.    SP Setting Lower Limit Stops the set point from going any lower than the SP setting lower limit...
  • Page 17 E5 K E5 K Option Mode - - ONLY Visible if an Option Board is Installed Multi-SP Function    Specifies the number of set points that will be used. Must be set to one to use SP Ramp feature. Available for the event input function.
  • Page 18 E5 K E5 K Option Mode - - ONLY Visible if an Option Board is Installed, continued Transfer output selections are ONLY available if a transfer TRANSFER OUTPUT SECTION board is installed. Transfer Output Type     Set when the transfer output function is in use. Determines which function the transfer output will re-transmit as a 4-20mA signal: SP, PV, SP Ramp, MV    ...
  • Page 19 E5 K E5 K ALARM MODE SELECTORS Alarm outputs are available if they are allocated as outputs. Factory setting is “2: Upper-limit alarm (deviation).” Alarm types Alarm output Setting number number When X is positive When X is negative Upper- and lower-limit alarm (deviation) Always ON Upper-limit alarm (deviation) Lower-limit alarm (deviation)
  • Page 20: How To Use The Error Display

    E5 K E5 K HOW TO USE THE ERROR DISPLAY When an error has occurred, the No.1 display alternately indicates error codes together with the current display item. This section describes how to check error codes on the display, and the actions that must be taken to remedy the problem. Input Error Meaning Input is in error.
  • Page 21: Fuzzy Self-Tuning

    E5 K E5 K FUZZY SELF-TUNING Note: You must turn ON the power supply to the LOAD either before or simultaneously with the start of Fuzzy self-tuning is a function that enables the E5 K to calculate Temperature Controller operation. the most suitable PID constants for the control output.
  • Page 22 E5 K E5 K Startup Conditions of DT Startup Conditions of HT 1. DT will start if the temperature that has been stable varies HT will be ON when there is hunting with four or more maximum due to external disturbance and the deflection of the temper- temperature values (extreme values) while SRT is not being ature exceeds the stable range, and then the temperature executed.
  • Page 23 E5 K E5 K Dimensions Unit: mm (inch) E5AK Panel Cutouts 13.5 110 min. (0.53) 100 (3.94) 96 (3.78) x 96 (3.78) 120 min. Note: 1. Recommended panel thickness is 1 to 8 mm. 2. Maintain the specified vertical and horizontal mounting space between each Unit. Units must not be closely mounted vertically or horizontally.
  • Page 24 E5 K E5 K E5CK-302 The E5CK-302 model has the same dimension and cutouts as the E5CK. ACCESSORIES (ORDER SEPARATELY) Terminal Cover for E5EK Terminal Cover for E5AK E53-COV0809 E53-COV08 22.05 (0.87) 43.2 (1.70) 43.2 (1.70) Terminal Cover for E5CK E53-COV07 44.3 (1.74)
  • Page 25: Installation

    E5 K E5 K Installation REMOVE CONTROLLER FROM REAR HOUSING E5AK and E5EK To pull out the internal mechanism from the housing, use a Phillips screwdriver matching the screw on the lower part of the front panel. 1. Turn the screw counterclockwise while pressing the hook on the upper part of the front panel. 2.
  • Page 26 E5 K E5 K SETTINGS Note: Always turn off the power supply to the Digital Controller before changing any switch settings. On a standard model, set up the Output Modules for control outputs 1 and 2 before mounting the Controller. On a position-proportional model, the Relay Output Module is already set.
  • Page 27 E5 K E5 K E5EK 1. Remove the Power Board in the order shown in the following 2. Insert the Option Board into the socket for option 1. The diagram. following diagram shows the relationship between the Option Board and mounting position. Power Board 3.
  • Page 28: Mounting Controller

    E5 K E5 K MOUNTING CONTROLLER E5AK and E5EK 1. Insert the controller into the panel’s mounting hole at the 3. Tighten the mounting bracket screws on the upper and lower position shown in the figure below. parts in small increments alternately and equally until the ratchet start to slide.
  • Page 29 E5 K E5 K MOUNTING TERMINAL COVER E5AK and E5EK E5CK 1. Fasten the terminals covers as follows by using the plastic 1. The E5CK-AA1-500 Controller is provided with a Terminal pins. Plastic pins are provided with the terminal covers. Cover (E53-COV07).
  • Page 30 E5 K E5 K WIRING TERMINALS FOR E5EK E5EK Terminal Arrangement Power supply Input power to terminal numbers 9 and 10. Power specifications AC100--240V are as follows: 100 to 240 VAC, 50/60 Hz, approx. 15 VA 50/60 Hz OPTION SENSOR INPUT TRSF: Transfer output...
  • Page 31: Sensor Input Wiring

    E5 K E5 K SENSOR INPUT WIRING E5AK Connect the sensor input to terminal numbers 11 to 14 and 33 as follows according to the input type. E5EK Connect the sensor input to terminal numbers 11 to 14 and 23 as follows according to the input type. E5CK Connect the sensor input to terminal numbers 6 to 8 as indicated here, according to the input type.
  • Page 32: Control Output

    E5 K E5 K CONTROL OUTPUT E5AK Control Output Terminal numbers 7 and 8 are for control output 1 (OUT1), and terminal numbers 5 and 6 are for control output 2 (OUT2). The following diagrams show the available Output Modules and their internal circuits. E5EK Control Output Terminal numbers 7 and 8 are for control output 1 (OUT1), and terminal numbers 5 and 6 are for control output 2 (OUT2).
  • Page 33: Auxiliary Output

    E5 K E5 K E5CK Control Output Terminal numbers 11 and 12 are for control output 1 (OUT1). The five output types and internal circuits are available according to the Output Board. Output type Relay 0 to 10 V 4 to 20mA/0 to 20mA Part number E53-R4R4 E53-Q4R4...
  • Page 34 E5 K E5 K CT INPUT/POTENTIOMETER (FOR E5AK AND E5EK ONLY) E5AK CT Input/Potentiometer E5EK CT Input/Potentiometer When using the HBA function on the E5AK-AA2 Controller, When using the HBA function on the E5EK-AA2 Controller, connect CT input (CT) to terminal numbers 15 to 17. When connect CT input (CT) to terminal numbers 15 to 17.
  • Page 35 E5 K E5 K OPTION BOARD WIRING E5AK Connect event inputs 1 and 2 (EV1/2) to terminal numbers 18 to 20, and event events 3 and 4 (EV3/4) to terminal numbers 24 to 26. However, note that terminal numbers 18 to 20 cannot be used on Controllers with a communications function. Connect the event inputs as follows: 31 32 Terminals 18 and 24 (COM) are connected internally.
  • Page 36 E5 K E5 K E5EK Connect event inputs 1 and 2 (EV1/2) to terminal numbers 18 to 20. However, note that terminal numbers 18 to 20 cannot be used on Controllers with a communications function. Connect the event inputs as follows: 21 22 4 to 20mA Event input 1 and 2...
  • Page 37 E5 K E5 K CONNECTION EXAMPLE OF DIGITAL CONTROLLER AND SSR Digital Controller Load Voltage output Heater terminal (for driv- Power supply INPUT LOAD ing SSR) for load Connectable Power SSR E5AK/E5EK Digital Controller with Voltage Output (12 VDC, 40 mA max.) E5CK Digital Controller with Voltage Output...
  • Page 38: Precautions When Wiring

    E5 K E5 K Precautions PRECAUTIONS WHEN WIRING • • Use wire ducts to separate input leads and power lines in Tighten the terminal screws using a torque no greater than order to protect the Controller and its lines from external 0.78 N m, or 8 kgf cm max.
  • Page 39 Output Unit is used. quenced circuits which incorporate a Digital Controller. Omron Europe B.V. EMA-ISD, tel:+31 23 5681390, fax:+31 23 5681397, http://www.eu.omron.com/ema Cat. No. GCTC12 1/99 Specifications subject to change without notice.

This manual is also suitable for:

E5ek-aa2-500E5ck-aa1-500E5ek-prr2-500E5ck-aa1-302E5ak-prr2-500E5ak series ... Show all

Table of Contents