Omron Q2A Series Technical Manual page 439

Driving quality 400 v class 0.55 kw to 315 kw
Hide thumbs Also See for Q2A Series:
Table of Contents

Advertisement

Setting
Function
15
FreqDetect 3
16
FreqDetect 4
17
@Fast Stop
18
@KEBridethru
19
@ShortCBraking
1A
@BaseblockNO
1B
@BaseblockNC
1C
FreqRefSource
1D
RunCmdSource
1E
Motor2 Select
1F
Restart Enable
20
FltReset Active
21
PolePos Detection
22
Ext 24V Supply
2F
@SpeedSearch
30
@TorqueLimit
31
@SpdLim@Trq
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the output frequency is higher than the setting value of "L4-03 [SpAgree Det.Level
(+/-)] + L4-04 [SpAgree Det.Width(+/-)]". After the terminal deactivates, the terminal stays off until the output
frequency is at the value of L4-03.
Note:
• The detection level set with L4-03 is a signed value. The drive will only detect in one direction.
• The drive uses the motor speed as the reference in CLV and CLV/PM.
ON : The output frequency is less than the value of L4-03 or is not higher than the value of L4-03 + L4-04.
OFF : The output frequency is higher than the value of L4-03 + L4-04.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the output frequency is higher than the value of L4-03 [SpAgree Det.Level(+/-)]. After
the terminal activates, the terminal stays on until the output frequency is at the value of L4-03 - L4-04.
ON : The output frequency is higher than the value of L4-03.
OFF : The output frequency is less than the value of "L4-03 - L4-04", or it is not higher than the value of L4-03.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the fast stop is in operation.
V/f
CL-V/f
OLV
CLV
AOLV
The activates during KEB Ride-Thru.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates during Short Circuit Braking.
Note:
When A1-02 = 8 [Control Method = EZ Vector], this function is available if you use a PM motor.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal turns on during baseblock. When the drive is in baseblock, the drive output transistor stops switching
and the drive will not make DC bus voltage.
ON : During baseblock
OFF : The drive is not in baseblock.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates during baseblock. When the drive is in baseblock, the drive output transistor stops
switching and does not make DC bus voltage.
ON : The drive is not in baseblock.
OFF : During baseblock
V/f
CL-V/f
OLV
CLV
AOLV
Shows the selected frequency reference source.
ON : The keypad is the frequency reference source.
OFF : b1-01 or b1-15 [Freq. Ref. Sel. 1 or Freq. Ref. Sel. 2] is the frequency reference source.
V/f
CL-V/f
OLV
CLV
AOLV
Shows the selected Run command source.
ON : The keypad is the Run command source.
OFF : b1-02 or b1-16 [Run Comm. Sel 1 or Run Comm. Sel 2] is the Run command source.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when motor 2 is selected.
ON : Motor 2 Selection
OFF : Motor 1 Selection
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the Auto Restart function is trying to restart after a fault.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal turns on when the drive receives the Reset command from the control circuit terminal, serial
communications, or the communication option.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when drive receives a Run command and the drive detects the motor magnetic pole position
of the PM motor.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when there is an external 24V power supply between terminals E24V-A0V.
ON : An external 24V power supply supplies power.
OFF : An external 24V power supply does not supply power.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the drive is doing speed search.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the torque reference is the torque limit set with L7 parameters, H3-02 [AI1 Function
Selection], H3-06 [AI3 Function Selection], or H3-10 [AI2 Function Selection].
V/f
CL-V/f
OLV
CLV
AOLV
The motor accelerates in the forward direction or the reverse direction after enabling torque control and the
externally input torque reference is disproportionate to the load. The output terminal activates when this speed is
not higher than a constant speed and the motor speed is at the speed limit. This does not include operation when the
drive is stopped.
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
11.8 H: TERMINALS
Ref.
703
704
704
704
705
705
705
705
705
705
705
706
706
706
706
706
706
439