12.7 H: TERMINALS
C: @Standby
Setting
Function
C
@Standby
ON : The Run command turns on and the magnetic contactor on the input side turns on.
OFF : The Run command turns off and the drive stops operating. Then, the magnetic contactor
on the input side turns off after the time set with b8-51 [Standby Mode Wait Time] elapses.
D: LO/RE Status
Setting
Function
D
LO/RE Status
ON : LOCAL
The keypad is the Run command source or the frequency reference source.
OFF : REMOTE
The Run command source or frequency reference source is an external source set with b1-01 [Freq. Ref. Sel. 1],
b1-15 [Freq. Ref. Sel. 2], b1-02 [Run Comm. Sel 1], or b1-16 [Run Comm. Sel 2].
E: EDM Safety
Setting
Function
E
EDM Safety
Note:
EDM = External Device Monitor
ON : Safety stop state
Terminals H1-HC and H2-HC are OFF or released (safety stop state).
700
Figure 12.87 Active Frequency Output Time Chart
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates after the drive stops operating and after the time set with b8-51 [Standby Mode Wait Time].
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the Run command source or frequency reference source is LOCAL.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal turns on (safety stop state) when the safety circuit and safety diagnosis circuit are operating correctly and when
terminals H1-HC and H2-HC are off (released).
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual