Omron Q2A Series Technical Manual page 536

Driving quality 400 v class 0.55 kw to 315 kw
Hide thumbs Also See for Q2A Series:
Table of Contents

Advertisement

12.2 b: APPLICATION
The drive uses the residual voltage from a short baseblock time to estimate the motor speed.
If there is not sufficient residual voltage, then the drive will inject DC current into the motor to estimate the motor
speed.
2 : Current Det2
The drive will inject DC current into the motor to estimate motor speed.
b3-25 SpSrch Wait Time
No.
Name
(Hex.)
b3-25
SpSrch Wait Time
(01C8)
Expert
If the drive detects these faults during speed search, increase the setting value:
• oC [Overcurrent]
• ov [Overvoltage]
• SEr [Speed Search Retries Exceeded]
b3-26 Dir. Determ. Level
No.
Name
(Hex.)
b3-26
Dir. Determ. Level
(01C7)
Expert
b3-27 SS@RUNbeforeBB
No.
Name
(Hex.)
b3-27
SS@RUNbeforeBB
(01C9)
Expert
Executes Speed Search from Fmax or Fref [H1-xx = 67/68] for initial speed searches or from the MFDI terminal.
0 : SS@RUNbeforeBB
1 : SS Always
b3-29 SpSrch BackEMF Threshold
No.
Name
(Hex.)
b3-29
SpSrch BackEMF
Threshold
(077C)
Expert
To make adjustments, gradually decrease the setting value. If you decrease the setting value too much, speed
search will not operate correctly.
b3-31 SpSrch I Ref Level
No.
Name
(Hex.)
b3-31
SpSrch I Ref Level
(0BC0)
Expert
Set this parameter as a ratio of E2-03 [Mot No-Load Current]. Sets a current level given that E2-03 is 30% of the
motor rated current when E2-03 ≤ Motor Rated Current × 0.3.
536
V/f
CL-V/f
OLV
CLV
AOLV
Sets the length of time the drive will wait to start the Speed Search Retry function.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the level to find the motor rotation direction. Increase the value if the drive cannot find the
direction.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the conditions necessary to start Speed Search.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the induced voltage for motors that use Speed Search. The drive will start Speed Search
when the motor induced voltage level is the same as the setting value. Usually it is not necessary
to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the current level that decreases the output current during Current Detection Speed Search.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Default
(Range)
0.5 s
(0.0 - 30.0 s)
Default
(Range)
1000
(40 - 60000)
Default
(Range)
0
(0, 1)
Default
(Range)
10%
(0 - 10%)
Default
(Range)
1.50
(1.50 - 3.50)

Hide quick links: