12.6 F: OPTIONS
F7-20 E/IP Power Scale Factor
No.
Name
(Hex.)
F7-20
E/IP Power Scale Factor
(03F8)
F7-21 E/IP Voltage Scale Factor
No.
Name
(Hex.)
F7-21
E/IP Voltage Scale Factor
(03F9)
F7-22 E/IP Time Scale Factor
No.
Name
(Hex.)
F7-22
E/IP Time Scale Factor
(03FA)
F7-23 to F7-32 DynOut.Ass116 P1 to 5 for CommCard and DynOut.Ass116 P6 to 10 for
CommCard
No.
Name
(Hex.)
F7-23 to F7-27
DynOut.Ass116 P1 to 5 for
CommCard
(03FB - 03FF)
DynOut.Ass116 P6 to 10
F7-28 to F7-32
for CommCard
(0370 - 0374)
F7-33 to F7-42 DynIn.Ass166 P1 to 10 for CommCard
No.
Name
(Hex.)
F7-33 to F7-42
DynIn.Ass166 P1 to 10 for
CommCard
(0375 - 037E)
F7-60 PZD1 WR(CtrlWrd)
No.
Name
(Hex.)
F7-60
PZD1 WR(CtrlWrd)
(0780)
F7-61 PZD2 WR(FRef)
No.
Name
(Hex.)
F7-61
PZD2 WR(FRef)
(0781)
F7-62 PZD3 Write
No.
Name
(Hex.)
F7-62
PZD3 Write
(0782)
662
V/f
CL-V/f
OLV
CLV
AOLV
Sets the scaling factor for the power monitor in the EtherNet/IP Class ID 2AH Object.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the scaling factor for the voltage monitor in the EtherNet/IP Class ID 2AH Object.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the scaling factor for the time monitor in the EtherNet/IP Class ID 2AH Object.
V/f
CL-V/f
OLV
CLV
AOLV
Sets Output Assembly 116. The drive writes the values from Output Assembly 116 to the Modbus
address register that is stored for each parameter. The drive will not write the values from Output
Assembly 116 to the registers when the Modbus address is 0.
V/f
CL-V/f
OLV
CLV
AOLV
Sets Input Assembly 166. The drive sends the values from the Modbus address registers stored for
each parameter to Input Assembly 166. The drive returns the default register value for the option
card when the Modbus address is 0 and the value sent to Input Assembly 166 is not defined.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Modbus address for PZD1 (PPO output). PZD1 (PPO output) functions as the STW when
F7-60 = 0, 1, or 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Modbus address for PZD2 (PPO output). PZD2 (PPO output) functions as the HSW when
F7-61 = 0, 1, or 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Modbus address for PZD3 (PPO output). A value of 0, 1, or 2 will disable the PZD3
(PPO output) write operation to the Modbus register.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Default
(Range)
0
(-15 - +15)
Default
(Range)
0
(-15 - +15)
Default
(Range)
0
(-15 - +15)
Default
(Range)
0
Default
(Range)
0
Default
(Range)
0
Default
(Range)
0
Default
(Range)
0