Omron Q2A Series Technical Manual page 639

Driving quality 400 v class 0.55 kw to 315 kw
Hide thumbs Also See for Q2A Series:
Table of Contents

Advertisement

Terminal
Terminal
Block
Name
8-bit
[F3-03 = 0]
TB2
DI0
1 digit (0 -
9)
DI1
DI2
DI3
DI4
2 digits (0 -
*2
15)
DI5
DI6
DI7
TB3
DI8
-
DI9
DIA
DIB
DIC
-
DID
DIE
DIF
TB1
SI
SIGN (encoded) signal
0: Forward run, 1: Reverse run
SE
SET (loaded) signal
1: Loads the value set for DI0 to DIF and SI.
D24V
Internal power supply: 24 V ± 5%
DIC
Input signal common
D0V
Internal power supply common: 0 V
SD
Cable sheath connection terminal (ungrounded)
FE
Cable sheath connection terminal (grounded)
*1
Setting F3-03 = 2 [D.In Data Length Select = 16-bit] enables F3-01 = 6 [D.In Funct Selection = BCD (5-digit), 0.01 Hz] and a
frequency between 0.00 Hz to 399.8 Hz can be set by the BCD. Note that terminal SI is also used as for data bits. Negative
commands cannot be input as encoding information (positive/negative) cannot be added to the data.
The minimum bit value for the first BCD digit is 2. For this reason, 0.02 Hz is the smallest setting unit available for this frequency
setting. An oPE05 [Run Cmd/Freq Ref Source Sel Err] occurs when F3-03 ≠ 2 while F3-01 = 6.
*2
The most significant digit can be set to a value between 0 to 15 when using "BCD, Signed". Other digits can be set to a value between
0 to 9.
F3-10 D0 Function Selection
No.
Name
(Hex.)
F3-10
D0 Function Selection
(0BE3)
Expert
F3-11 D1 Function Selection
No.
Name
(Hex.)
F3-11
D1 Function Selection
(0BE4)
Expert
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Table 12.31 DI-A3 Terminal Function Selection
BCD, Signed
[F3-01 = 0 to 5]
12-bit
[F3-03 = 1]
1
1 digit (0 -
1
9)
2
2
4
4
8
8
1
2 digits (0 -
1
9)
2
2
4
4
8
8
-
3 digits (0 -
1
*2
15)
-
2
-
4
-
8
-
-
-
-
-
-
-
-
-
V/f
CL-V/f
OLV
CLV
Sets the function for terminal D0 of the DI-A3 when F3-01 = 8 [D.In Funct Selection = MF
Digital Input].
V/f
CL-V/f
OLV
CLV
Sets the function for terminal D1 of the DI-A3 when F3-01 = 8 [D.In Funct Selection = MF
Digital Input].
BCD, Unsigned
[F3-01 = 6]
16-bit
[F3-03 = 2]
1 digit (0 -
1
1 digit (0,
9)
2, 4, 6, 8)
2
4
8
2 digits (0 -
9)
2 digits (0 -
1
9)
2
4
8
3 digits (0 -
9)
3 digits (0 -
-
9)
-
-
-
4 digits (0 -
9)
4 digits (0 -
-
*2
15)
-
-
-
5 digits (0 -
3)
Description
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
12.6 F: OPTIONS
Binary, Signed
*1
[F3-01 = 7]
8-bit
12-bit
[F3-03 =
[F3-03 = 1]
0]
2
bit 0
bit 0
4
bit 1
bit 1
8
bit 2
bit 2
1
bit 3
bit 3
2
bit 4
bit 4
4
bit 5
bit 5
8
bit 6
bit 6
1
bit 7
bit 7
2
-
bit 8
4
-
bit 9
8
-
bit 10
1
-
bit 11
2
-
-
4
-
-
8
-
-
1
-
-
2
SIGN (encoded) signal
0: Forward run, 1: Reverse run
Default
(Range)
0
(0 - 4, 6 - 19F)
Default
(Range)
0
(0 - 4, 6 - 19F)
16-bit
[F3-03 =
2]
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
bit 8
bit 9
bit 10
bit 11
bit 12
bit 13
bit 14
bit 15
12
639

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents