11.10 n: SPECIAL

n3: HIGHSLIP/OVEREXCITATION BRAKE

No.
Name
(Hex.)
n3-01
HSB Dec Freq Width
(0588)
Expert
n3-02
HSB CurrLim Level
(0589)
Expert
n3-03
HSB DwellTime@Stop
(058A)
Expert
n3-04
HSB Overload Time
(058B)
Expert
n3-13
OverExcBr Gain
(0531)
n3-14
OverExcBr Harmonics
Selection
(0532)
Expert
n3-21
OverExcBr Current
Level
(0579)
n3-23
OverExcBr Operation
(057B)

n4: ADV. OPEN LOOP VECTOR TUNING

No.
Name
(Hex.)
n4-60
LoSpeed Comp Gain
(1B80)
n4-61
LoSpeed Comp
Frequency Level
(1B81)
n4-62
Reg LoSpd Cmp Gain
(1B82)
n4-63
HF SpdEstim Response
(1B83)
n4-64
LF SpdEstim Response
(1B84)
n4-65
HF FlxEstim Response
(1B85)
n4-66
LF FlxEstim Response
(1B86)
n4-67
SpEstim Gain
SwFrequency
(1B87)
458
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets how much the drive lowers the output frequency during high-slip braking as a
percentage where E1-04 [Max Output Frequency] = 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the maximum current output during high-slip braking as a percentage where E2-01
[Mot Rated Current (FLA)] = 100%. Also set the current suppression to prevent
exceeding drive overload tolerance.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the dwell time, a length of time when high-slip braking is ending and during which
the motor speed decreases and runs at a stable speed. For a set length of time, the drive
will hold the actual output frequency at the minimum output frequency set in E1-09.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time used to detect oL7 [High Slip Braking Overload], which occurs when the
output frequency does not change during high-slip braking. Usually it is not necessary
to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain value that the drive multiplies by the V/f pattern output value during
overexcitation deceleration to calculate the overexcitation level.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that injects harmonic signals during overexcitation deceleration.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the upper limit of the current that is suppressed at the time of overexcitation
deceleration, where the drive rated current = 100% value.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the direction of motor rotation where the drive will enable overexcitation.
1 : Enabled@Both directions
2 : Enabled@FW direction
3 : Enabled@REV direction
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets a compensation gain to improve the control qualities for motoring loads in the low
speed range.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a frequency at which the settings for n4-60 [LoSpeed Comp Gain], n4-62 [Reg
LoSpd Cmp Gain] are enabled. When the output frequency < n4-61, the drive adjusts
the torque to agree with the settings for n4-60 and n4-62. Usually it is not necessary to
change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a compensation gain to improve the control qualities for regenerative loads in the
low speed range.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the responsiveness of the speed estimation in high speed ranges, where the output
frequency is ≥ n4-67 [SpEstim Gain SwFrequency].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the responsiveness of the speed estimation in low speed ranges, where 0 ≤ the
output frequency, which is < n4-67 [SpEstim Gain SwFrequency].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the responsiveness of the magnetic flux estimation in high speed ranges, where the
output frequency is ≥ n4-67 [SpEstim Gain SwFrequency]. Usually it is not necessary to
change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the responsiveness of the magnetic flux estimation in low speed ranges, where 0 ≤
the output frequency, which is < n4-67 [SpEstim Gain SwFrequency]. Usually it is not
necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the switching frequency for estimation gain for these parameters:
n4-63 [HF SpdEstim Response]
n4-64 [LF SpdEstim Response]
n4-65 [HF FlxEstim Response]
n4-66 [LF FlxEstim Response]
Usually it is not necessary to change this setting.
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Default
Ref.
(Range)
5%
787
(1 - 20%)
Determined by C6-01,
787
L8-38
(0 - 200%)
1.0 s
788
(0.0 - 10.0 s)
40 s
788
(30 - 1200 s)
1.10
788
(1.00 - 1.40)
0
788
(0, 1)
100%
789
(0 - 150%)
1
789
(1 - 3)
Default
Ref.
(Range)
1.000
789
(0.500 - 2.000)
6.00 Hz
789
(0.50 - 12.00 Hz)
1.000%
790
(0.500 - 2.000%)
1.000
790
(0.001 - 5.000)
1.000
790
(0.001 - 5.000)
0.90
790
(0.50 - 1.50)
0.90
790
(0.50 - 1.50)
6.00 Hz
791
(0.00 - E1-04)