2.3 Installation Position and Distance
2.3
Installation Position and Distance
Install the drive vertically for sufficient cooling airflow.
Note:
Contact the manufacturer or your sales representative for more information about installing drive models on their side.
A - Vertical installation
◆
Single Drive Installation
Use the clearances specified to install the drive. Make sure that there is sufficient space for wiring and airflow.
A - 50 mm (2 in.) minimum
B - 30 mm (1.2 in.) minimum on both
◆
Install Drives Side-by-Side
Users can install drive models 4002xB to 4044xB side-by-side.
Install the drives as specified by
Derate the output current to align with the ambient temperature.
32
Figure 2.1 Installation Position
sides
Figure 2.2 Installation Distances for One Drive
Figure
2.3. Set L8-35 = 1 [Installation Selection = Side-by-Side Mounting].
B - Horizontal installation
C - 120 mm (4.7 in.) minimum above
and below
D - Airflow direction
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual