Omron Q2A Series Technical Manual page 432

Driving quality 400 v class 0.55 kw to 315 kw
Hide thumbs Also See for Q2A Series:
Table of Contents

Advertisement

11.8 H: TERMINALS
Setting
Function
11
LOC/REM Sel.
12
AI Input Sel
13
Spd/Trq Switch
14
AI Trq Polarity
15
FWD/REV Det
16
Ref Sample
17
Ac/Dec Hold
18
Ac/Dec Time1
19
Ac/Dec Time2
1A
Drive Enable
1B
Baseblock NO
1E
Baseblock NC
20 to 2F
External Fault
30
DCInj Cmd
31
Zero Servo
432
V/f
CL-V/f
OLV
CLV
AOLV
Sets drive control for the keypad (LOCAL) or an external source (REMOTE).
ON : LOCAL
OFF : REMOTE
V/f
CL-V/f
OLV
CLV
AOLV
Sets the command that enables or disables the terminals selected in H3-14 [An.In Term.Enable Sel].
ON : Input to the terminal selected with H3-14 is enabled
OFF : Input to the terminal selected with H3-14 is disabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to switch between torque control and speed control.
ON : Torque control
OFF : Speed control
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rotation direction of the external torque reference.
ON : External torque reference reverse direction
OFF : External torque reference forward direction
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rotation direction of the motor when in Simple Closed Loop V/f Control method and F1-21, F1-37 = 0
[Encoder Option Function Selection = A Pulse Detection], or when in Closed Loop V/f Control method.
ON : Reverse
OFF : Forward
V/f
CL-V/f
OLV
CLV
AOLV
Sets the command to sample the frequency reference at terminals AI1, AI2, or AI3 and hold the frequency
reference at that frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Momentarily pauses motor acceleration and deceleration when the terminal is turned ON, retains the output
frequency that was stored in the drive at the time of the pause, and restarts motor operation.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the drive to use C1-01, C1-02 [Accel Time 1, Decel Time 1] or C1-03, C1-04 [Accel Time 2, Decel Time 2].
V/f
CL-V/f
OLV
CLV
AOLV
Set this function and H1-xx = 18 [Ac/Dec Time1] together. Sets the drive to use C1-05, C1-06 [Accel Time 3, Decel
Time 3] or C1-07, C1-08 [Accel Time 4, Decel Time 4].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to show dnE [Drive Enabled] on the keypad and ignore Run commands when the terminal is
OFF.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the command that stops drive output and coasts the motor to stop when the input is ON.
ON : Baseblock (drive output stop)
OFF : Normal operation
V/f
CL-V/f
OLV
CLV
AOLV
Sets the command that stops drive output and coasts the motor to stop when the input terminal is OFF.
ON : Normal operation
OFF : Baseblock (drive output stop)
V/f
CL-V/f
OLV
CLV
AOLV
Sets a command to stop the drive when a failure or fault occurs on an external device.
20 : ExF NO-AlRmp
21 : ExF NC-AlRmp
22 : ExF NO-RnRmp
23 : ExF NC-RnRmp
24 : ExF NO-AlCoast
25 : ExF NC-AlCoast
26 : ExF NO-RnCoast
27 : ExF NC-RnCoast
28 : ExF NO-AlFStop
29 : ExF NC-AlFStop
2A : ExF NO-RnFStop
2B : ExF NC-RnFStop
2C : ExF NO-AlAlarm
2D : ExF NC-AlAlarm
2E : ExF NO-RnAlarm
2F : ExF NC-RnAlarm
V/f
CL-V/f
OLV
CLV
AOLV
Sets the command to use DC Injection Braking to stop the motor.
Note:
When A1-02 = 8 [Control Method = EZ Vector], this function is available if you use a PM motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to hold a stopped motor.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Ref.
673
674
674
674
674
674
675
675
675
675
676
676
676
677
677

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents