No.
Name
(Hex.)
E3-10
M2 Min Out Voltage
(0320)
E3-11
M2 Mid B Frequency
(0345)
Expert
E3-12
M2 Min Out Voltage
(0346)
Expert
E3-13
M2 Base Voltage
(0347)
Expert

E4: MOTOR 2 PARAMETERS

No.
Name
(Hex.)
E4-01
M2 Rated Current (FLA)
(0321)
E4-02
M2 Rated Slip
(0322)
E4-03
M2 No-Load Current
(0323)
E4-04
M2 Pole Count
(0324)
E4-05
M2 L-L Resistance
(0325)
E4-06
M2 Leak Inductance
(0326)
E4-07
M2 Satur Coeff 1
(0343)
E4-08
M2 Satur Coeff 2
(0344)
E4-09
M2 Mech Loss
(033F)
Expert
E4-10
M2 Iron Loss
(0340)
E4-11
M2 Rated Power (kW)
(0327)

E5: PM MOTOR SETTINGS

No.
Name
(Hex.)
E5-01
PM Mot Code Selection
(0329)
E5-02
PM Mot Rated Power
(kW)
(032A)
E5-03
PM Mot Rated Current
(FLA)
(032B)
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum output voltage for the motor 2 V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a middle output frequency for the motor 2 V/f pattern. Set this parameter to adjust
the V/f pattern for the constant output range. Usually it is not necessary to change this
setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a middle output voltage for the motor 2 V/f pattern. Set this parameter to adjust the
V/f pattern for the constant output range. Usually it is not necessary to change this
setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the base voltage for the motor 2 V/f pattern. Set this parameter to adjust the V/f
pattern for the constant output range. Usually it is not necessary to change this setting.
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor rated current for motor 2 in amps.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor rated slip for motor 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the no-load current for motor 2 in amps when operating at the rated frequency and
the no-load voltage.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of poles for motor 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the line-to-line resistance for the motor 2 stator windings.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the voltage drop from motor 2 leakage inductance as a percentage of Motor Rated
Voltage when motor 2 operates at the rated frequency and rated current.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor 2 iron-core saturation coefficient at 50% of the magnetic flux.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor 2 iron-core saturation coefficient at 75% of the magnetic flux.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the mechanical loss of motor 2. Motor rated power (kW) is 100%. Usually it is not
necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor iron loss for motor 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor 2 rated power in 0.01 kW increments (1 HP = 0.746 kW).
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor code for Yaskawa PM motors. The drive uses the motor code to set some
parameters to their correct settings automatically.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the PM motor rated power.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the PM motor rated current (FLA).
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
11.6 E: MOTOR
Default
Ref.
(Range)
Determined by E3-01
620
(400 V Class: 0.0 - 510.0
V)
0.0 Hz
620
(0.0 - E3-04)
0.0 V
621
(400 V Class: 0.0 - 510.0
V)
0.0 V
621
(400 V Class: 0.0 - 510.0
V)
Default
Ref.
(Range)
Determined by o2-04
621
and C6-01
(10% to 200% of the
drive rated current)
Determined by o2-04
621
and C6-01
(0.000 - 20.000 Hz)
Determined by o2-04
622
and C6-01
(0 to E4-01)
4
622
(2 - 120)
Determined by o2-04
622
and C6-01
(0.000 - 65.000 Ω)
Determined by o2-04,
622
C6-01
(0.0 - 60.0%)
0.50
623
(0.00 - 0.50)
0.75
623
(E4-07 - 0.75)
0.0%
623
(0.0 - 10.0%)
Determined by o2-04
623
and C6-01
(0 - 65535 W)
Determined by o2-04
623
and C6-01
(0.00 - 650.00 kW)
Default
Ref.
(Range)
Determined by A1-02,
624
o2-04, and C6-01
(0000 - FFFF)
Determined by E5-01
624
(0.10 - 650.00 kW)
Determined by E5-01
201
(10% to 200% of the
drive rated current)
417