Omron Q2A Series Technical Manual page 341

Driving quality 400 v class 0.55 kw to 315 kw
Hide thumbs Also See for Q2A Series:
Table of Contents

Advertisement

2.
Tighten the M3 screws to a tightening torque of 0.5 N∙m to 0.6 N∙m (4.4 lb.∙in. to 5.3 lb.∙in.).
3.
Install the front cover and the keypad to their initial positions.
4.
Check o2-04 [Drive KVA Selection].
Note:
• When you save parameter information in a keypad that you installed before you replaced the terminal block, make sure that you use
that keypad to restore the parameter data.
• To reset the performance life monitors for the components, set Maintenance Period o4-01 to o4-13.
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Figure 8.74 Safety the Terminal Block
8.5 Replace the Drive
341