O3: Copy Function - Omron Q2A Series Technical Manual

Driving quality 400 v class 0.55 kw to 315 kw
Hide thumbs Also See for Q2A Series:
Table of Contents

Advertisement

No.
Name
(Hex.)
o2-05
LCD FreqRef
Mode@Home Screen
(0509)
o2-06
Keypad Disconnect
Detection
(050A)
o2-07
Keypad Dir@Power-Up
(0527)
o2-09
Region Code for
Initialization
(050D)
o2-23
Ext24V Off Warning
Display
(11F8)
o2-26
Ext24V Mode Warning
Display
(1563)
o2-27
BLE Disconn.
Selection@BLE Ctrl
(1565)

o3: COPY FUNCTION

No.
Name
(Hex.)
o3-01
COPY Keypad Selection
of Mode
(0515)
o3-02
COPY Allow Selection
(0516)
o3-04
COPY Memory
Selection
(0B3E)
o3-05
COPY Items Selection
(0BDA)
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that makes it necessary to push the
frequency reference value with the keypad when in Drive Mode.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that stops the drive if you disconnect the keypad connection cable
from the drive or if you damage the cable while the keypad is the Run command source.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the direction of motor rotation when the drive is energized and the keypad is the
Run command source.
0 : Forward
1 : Reverse
-
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to give a warning when the backup external 24 V power supply turns
off when the main circuit power supply is in operation.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
When you connect a backup external 24 V power supply, this parameter sets the
function to trigger an alarm when the main circuit power supply voltage decreases.
Note:
The drive will not run when it is operating from one 24-V external power supply.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets drive operation if the Bluetooth device is disconnected when you operate the drive
in Bluetooth Mode.
0 : Ramp->Stop
1 : Coast->Stop
2 : Fast Stop (C1-09)
3 : Alarm Only
4 : No Alarm Display
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that saves and copies drive parameters to a different drive with the
keypad.
0 : Copy Select
1 : Bck (Drive->OPE)
2 : Res (OPE->Drive)
3 : Verify (Check)
4 : Del (Clear OPE Memory)
V/f
CL-V/f
OLV
CLV
AOLV
Sets the copy function when o3-01 = 1 [COPY Keypad Selection of Mode = Bck
(Drive->OPE)].
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the storage location for drive parameters when you back up and restore parameters.
This parameter is only available with an LCD keypad.
0 : Memory 1
1 : Memory 2
2 : Memory 3
3 : Memory 4
V/f
CL-V/f
OLV
CLV
AOLV
Sets which parameters are backed up, restored, and referenced. This parameter is only
available with an LED keypad.
0 : Std
1 : Std+Solution
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
button to change the
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
11.11 o: KEYPAD
Default
Ref.
(Range)
0
812
(0, 1)
Determined by o2-09
812
(0, 1)
0
813
(0, 1)
-
-
0
813
(0, 1)
0
813
(0, 1)
3
813
(0 - 4)
Default
Ref.
(Range)
0
814
(0 - 4)
0
814
(0, 1)
0
814
(0 - 3)
0
814
(0, 1)
465
11