Omron Q2A Series Technical Manual page 546

Driving quality 400 v class 0.55 kw to 315 kw
Hide thumbs Also See for Q2A Series:
Table of Contents

Advertisement

12.2 b: APPLICATION
The drive does D control on the difference between the feedback value and the PID setpoint output through U5-01
[PID Feedback].
1 : Feedback 2
The drive does D control on the difference between the feedback value and the PID setpoint output through U5-05
[PID Diff.Feedbk].
b5-72 PID D-FF Mode
No.
Name
(Hex.)
b5-72
PID D-FF Mode
(01E7)
0 : D=Fdback
The drive does D control on the feedback output through U5-06 [PID AdjustFeedback].
1 : D=FdFwd
The drive adds the frequency reference to the PID output. The drive does D control on the feedback output
through U5-06 [PID AdjustFeedback].
b5-02 Proportional Gain (P)
No.
Name
(Hex.)
b5-02
Proportional Gain (P)
(01A6)
RUN
Larger values decrease errors, but can cause oscillations. Smaller values let too much offset between the setpoint
and feedback.
Set b5-02 = 0.00 to disable P control.
b5-03 Integral Time (I)
No.
Name
(Hex.)
b5-03
Integral Time (I)
(01A7)
RUN
Set a short integral time in b5-03 to remove the offset more quickly. If the integral time is too short, overshoot or
oscillation can occur.
Set b5-03 = 0.00 to disable I control.
b5-04 Integral Limit
No.
Name
(Hex.)
b5-04
Integral Limit
(01A8)
RUN
546
V/f
CL-V/f
OLV
CLV
AOLV
Determines whether the D part is in the feedback path or used for feed forward control.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the proportional gain (P) that is applied to PID input.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the integral time (I) that is applied to PID input.
Figure 12.33 Integral Time and Deviation
V/f
CL-V/f
OLV
CLV
AOLV
Sets the upper limit for I control as a percentage of E1-04 [Max Output Frequency].
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Default
(Range)
0
(0, 1)
Default
(Range)
1.00
(0.00 - 25.00)
Default
(Range)
1.0 s
(0.0 - 360.0 s)
Default
(Range)
100.0%
(0.0 - 100.0%)