d1-13 Reference 13
No.
Name
(Hex.)
d1-13
Reference 13
(028E)
RUN
Note:
• The upper limit value changes when the E1-04 [Max Output Frequency] and d2-01 [FRef Upper Limit] values change.
• When A1-02 = 6, 7 [Control Method = PM AOLVector, PM CLVector], the drive changes o1-03 = 1 [0.01% (100%=E1-04)].
• This parameter sets the frequency reference of Multi-Step Speed 13.
d1-14 Reference 14
No.
Name
(Hex.)
d1-14
Reference 14
(028F)
RUN
Note:
• The upper limit value changes when the E1-04 [Max Output Frequency] and d2-01 [FRef Upper Limit] values change.
• When A1-02 = 6, 7 [Control Method = PM AOLVector, PM CLVector], the drive changes o1-03 = 1 [0.01% (100%=E1-04)].
• This parameter sets the frequency reference of Multi-Step Speed 14.
d1-15 Reference 15
No.
Name
(Hex.)
d1-15
Reference 15
(0290)
RUN
Note:
• The upper limit value changes when the E1-04 [Max Output Frequency] and d2-01 [FRef Upper Limit] values change.
• When A1-02 = 6, 7 [Control Method = PM AOLVector, PM CLVector], the drive changes o1-03 = 1 [0.01% (100%=E1-04)].
• This parameter sets the frequency reference of Multi-Step Speed 15.
d1-16 Reference 16
No.
Name
(Hex.)
d1-16
Reference 16
(0291)
RUN
Note:
• The upper limit value changes when the E1-04 [Max Output Frequency] and d2-01 [FRef Upper Limit] values change.
• When A1-02 = 6, 7 [Control Method = PM AOLVector, PM CLVector], the drive changes o1-03 = 1 [0.01% (100%=E1-04)].
• This parameter sets the frequency reference of Multi-Step Speed 16.
d1-17 Jog Reference
No.
Name
(Hex.)
d1-17
Jog Reference
(0292)
RUN
Note:
• The upper limit value changes when the E1-04 [Max Output Frequency] and d2-01 [FRef Upper Limit] values change.
• When A1-02 = 6, 7 [Control Method = PM AOLVector, PM CLVector], the drive changes o1-03 = 1 [0.01% (100%=E1-04)].
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency reference in the units from o1-03 [FrqDisplay Unit Selection].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency reference in the units from o1-03 [FrqDisplay Unit Selection].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency reference in the units from o1-03 [FrqDisplay Unit Selection].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency reference in the units from o1-03 [FrqDisplay Unit Selection].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the JOG frequency reference in the units from o1-03 [FrqDisplay Unit Selection]. Set H1-xx:
MFDI Function Select = 6 [Jog Reference] to use the Jog frequency reference.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
12.4 d: REFERENCE
Default
(Range)
0.00 Hz
(0.00 - 590.00 Hz)
Default
(Range)
0.00 Hz
(0.00 - 590.00 Hz)
Default
(Range)
0.00 Hz
(0.00 - 590.00 Hz)
Default
(Range)
0.00 Hz
(0.00 - 590.00 Hz)
Default
(Range)
6.00 Hz
(0.00 - 590.00 Hz)