No.
C5-02 ASR ITime 1
C5-03 ASR PGain 2
C5-04 ASR ITime 2
C5-06 ASR Delay Time
C5-07 ASR Gain Switch Frequency
C6-02 Carrier Frequency Selection
d3-01 Jump Frequency 1
d3-02 Jump Frequency 2
d3-03 Jump Frequency 3
d3-04 Jump Frequency Width
d5-02 Torque Ref Delay Time
E1-04 Max Output Frequency
E1-05 Max Output Voltage
E1-06 Base Frequency
E1-07 Mid A Frequency
E1-08 Mid A Voltage
E1-09 Min Output Frequency
E1-10 Min Output Voltage
F1-01 Enc1 Pulse Count (PPR)
F1-05 Enc1 Rotat Selection
F1-09 Overspeed Delay Time
H4-20 An.Pwr Mon 100% Level
L1-01 Motor Cool Type for OL1 Calc
L3-05 StallP@RUN Enable
L3-20 DCBus VoltAdj Gain
L3-21 OVSup Acc/Dec Gain
L3-36 VibSup Gain@Accel
L4-01 SpAgree Det.Level
L4-02 SpAgree Det.Width
L4-03 SpAgree Det.Level(+/-)
L4-04 SpAgree Det.Width(+/-)
L8-38 Carrier Reduction Mode
L8-40 Carrier Red Off-Delay Time
n1-15 PWM VOffset Calibration
o1-03 FrqDisplay Unit Selection
o1-04 V/f Pattern Unit for Display
*1
The setting range is 0.0 to 100.0 when A1-02 = 6 or 7 [Control Method = PM AOLVector or PM CLVector].
*2
The setting range is 0.0 to 40.0 when A1-02 = 6 or 7 [Control Method = PM AOLVector or PM CLVector].
*3
The default setting varies depending on the setting of ND/HD Duty Selection.
*4
This is the value for 200 V class drives. Double the value for 400 V class drives.
*5
The setting range is -100.0 to +100.0 when A1-02 = 6 or 7 [Control Method = PM AOLVector or PM CLVector].
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Setting Range
Unit
0.000 - 60.000
0.001 s
0.00 - 300.00
0.01
0.000 - 10.000
0.001 s
0.000 - 0.500
0.001 s
*1
0.0 - 400.0
0.1
1 - F
1
*1
0.0 - 400.0
0.1
*1
0.0 - 400.0
0.1
*1
0.0 - 400.0
0.1
*2
0.0 - 20.0
0.1
0 - 1000
1 ms
*3
40.0 - 400.0
0.1 Hz
*4
0.0 - 255.0
0.1 V
0.0 - 400.0
0.1 Hz
0.0 - 400.0
0.1 Hz
*4
0.0 - 255.0
0.1 V
0.0 - 400.0
0.1 Hz
*4
0.0 - 255.0
0.1 V
0 - 60000
1 ppr
0 - 1
1
0.0 - 2.0
0.1 s
0.00 - 650.00
0.01
0 - 4
1
0 - 3
1
0.00 - 5.00
0.01
0.10 - 10.00
0.01
0.0 - 100.0
0.1
*1
0.0 - 400.0
0.1
*2
0.0 - 20.0
0.1
*5
-400.0 - +400.0
0.1
*2
0.0 - 20.0
0.1
0 - 2
1
0.00 - 2.00
0.01 s
0 - 2
1
0 - 3
1
0 - 1
1
11.16 A1-02 [Control Method] Dependent Parameters
Control Method
PM OLVector
PM AOLVector
(5)
(6)
0.500
0.500
-
10.00
-
0.500
-
0.016
0.0 Hz
0.0 %
2
2
0.0 Hz
0.0 %
0.0 Hz
0.0 %
0.0 Hz
0.0 %
1.0 Hz
1.0 %
-
-
Determined by E5-
Determined by E5-
01
01
Determined by E5-
Determined by E5-
01
01
Determined by E5-
Determined by E5-
01
01
-
-
-
-
Determined by E5-
Determined by E5-
01
01
-
-
1024
1024
1
1
-
-
Determined by E5-
Determined by E5-
01
01
4
4
1
-
0.65
0.65
1.00
1.00
-
-
0.0 Hz
0.0 %
2.0 Hz
4.0%
0.0 Hz
0.0 %
2.0 Hz
4.0%
0
0
0.00
0.00
1
1
0
1
-
1
PM CLVector
EZ Vector
(7)
(8)
0.500
0.500
20.00
10.00
0.500
0.500
0.004
0.004
0.0 %
0.0 %
2
2
0.0 %
0.0 %
0.0 %
0.0 %
0.0 %
0.0 %
1.0 %
1.0 %
0
-
Determined by E5-
-
01
Determined by E5-
-
01
Determined by E5-
-
01
-
-
-
-
0.0
-
-
-
1024
600
1
0
0.0
-
Determined by E5-
Determined by E9-
01
07
Determined by E9-
5
01
-
3
0.65
0.65
1.00
1.00
-
-
0.0 %
0.0 %
4.0%
4.0%
0.0 %
0.0 %
4.0%
4.0%
0
0
0.00
0.00
1
1
1
1
1
-
485
11

Hide quick links: