D6: Field Weakening / Forcing; D7: Offset Frequency - Omron Q2A Series Technical Manual

Driving quality 400 v class 0.55 kw to 315 kw
Hide thumbs Also See for Q2A Series:
Table of Contents

Advertisement

11.5 d: REFERENCE
No.
Name
(Hex.)
d5-04
Speed Limit
(029D)
d5-05
Speed Limit Bias
(029E)
d5-06
Spd/Trq Chg Time
(029F)
d5-08
UniDir Speed Bias
(02B5)

d6: FIELD WEAKENING / FORCING

No.
Name
(Hex.)
d6-01
Field Weak Level
(02A0)
d6-02
Field Weak FqLimit
(02A1)
d6-03
Field Force Selection
(02A2)
d6-06
Field Force Limit
(02A5)

d7: OFFSET FREQUENCY

No.
Name
(Hex.)
d7-01
Offset Frq 1
(02B2)
RUN
d7-02
Offset Frq 2
(02B3)
RUN
d7-03
Offset Frq 3
(02B4)
RUN
414
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the speed limit during Torque Control as a percentage of E1-04 [Max Output
Frequency]. Set d5-03 = 2 [Speed Limit Selection = d5-04 Setting] before you set this
parameter.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a bias to the speed limit as a percentage of E1-04 [Max Output Frequency].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the delay time to switch between Speed Control and Torque Control. Set H1-xx =
13 [H1-xx: MFDI Function Select = Spd/Trq Switch] before you set this parameter.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the direction of the speed limit reference to which Speed Limit Bias [d5-05]
applies.
0 : Disabled
1 : Enabled
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the drive output voltage as a percentage of E1-05 [Max Output Voltage] when H1-
xx = 44 [Field Weakening] is activated.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum output frequency to start field weakening.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the field forcing function.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the maximum level that Field Forcing can increase the excitation current reference
as a percentage of E2-03 [Mot No-Load Current]. Usually it is not necessary to change
this setting.
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the value to add to or subtract from the frequency reference when H1-xx = 0E [H1-
xx: MFDI Function Select = Offset Frq 1] as a percentage of E1-04 [Max Output
Frequency].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the value to add to or subtract from the frequency reference when H1-xx = 0F [H1-
xx: MFDI Function Select = Offset Frq 2] as a percentage of E1-04 [Max Output
Frequency].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the value to add to or subtract from the frequency reference when H1-xx = 10 [H1-
xx: MFDI Function Select = Offset Frq 3] as a percentage of E1-04 [Max Output
Frequency].
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Default
Ref.
(Range)
0%
606
(-120 - +120%)
10%
606
(0 - 120%)
0 ms
606
(0 - 1000 ms)
1
606
(0, 1)
Default
Ref.
(Range)
80%
607
(0 - 100%)
0.0 Hz
607
(0.0 - 590.0 Hz)
0
607
(0, 1)
400%
607
(100 - 400%)
Default
Ref.
(Range)
0.0%
608
(-100.0 - +100.0%)
0.0%
608
(-100.0 - +100.0%)
0.0%
608
(-100.0 - +100.0%)

Hide quick links: