Omron Q2A Series Technical Manual page 68

Driving quality 400 v class 0.55 kw to 315 kw
Hide thumbs Also See for Q2A Series:
Table of Contents

Advertisement

3.2 Standard Connection Diagram
*1
Set the wiring sequence to de-energize the drive with the fault relay output. If the drive outputs a fault during
fault restart when you use the fault restart function, set L5-02 = 2 [Fault@Reset Select = Enable Fault
Output] to de-energize the drive. Be careful when you use a cut-off sequence. The default setting for L5-02 =
1 [Fault@Reset Select = Disable Fault Output].
*2
When you install a DC reactor, you must remove the jumper between terminals +1 and +2.
68
Figure 3.1 Standard Drive Connection Diagram
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual