11.7 F: OPTIONS
No.
Name
(Hex.)
F7-13
Addr Mode@Startup
(03F1)
F7-14
Duplex Mode Selection
(03F2)
F7-15
Comm. BaudRate
(03F3)
F7-16
Timeout Value
(03F4)
F7-17
E/IP Speed Scale Factor
(03F5)
F7-18
E/IP Current Scale
Factor
(03F6)
F7-19
E/IP Torque Scale Factor
(03F7)
F7-20
E/IP Power Scale Factor
(03F8)
F7-21
E/IP Voltage Scale
Factor
(03F9)
F7-22
E/IP Time Scale Factor
(03FA)
F7-23 to F7-27
DynOut.Ass116 P1 to 5
for CommCard
(03FB - 03FF)
DynOut.Ass116 P6 to 10
F7-28 to F7-32
for CommCard
(0370 - 0374)
F7-33 to F7-42
DynIn.Ass166 P1 to 10
for CommCard
(0375 - 037E)
F7-60
PZD1 WR(CtrlWrd)
(0780)
F7-61
PZD2 WR(FRef)
(0781)
F7-62
PZD3 Write
(0782)
F7-63
PZD4 Write
(0783)
428
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the method to set option card IP addresses.
0 : Static
1 : BOOTP
2 : DHCP
Note:
• The following setting values are available when using the PROFINET
communication option card (SI-EP3).
–0: Static
–2: DCP
• When F7-13 = 0, set parameters F7-01 to F7-12 [Subnet Mask 3 to Gateway Addr
4] to set the IP Address. Be sure to set a different IP address for each drive on the
network.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the duplex mode setting method.
0 : Half/Half
1 : Auto/Auto
2 : Full/Full
3 : Half/Auto
4 : Half/Full
5 : Auto/Half
6 : Auto/Full
7 : Full/Half
8 : Full/Auto
V/f
CL-V/f
OLV
CLV
AOLV
Sets the communications speed.
10 : 10/10 Mbps
102 : 100/10 Mbps
V/f
CL-V/f
OLV
CLV
AOLV
Sets the detection time for a communications timeout.
Note:
Set this parameter to 0.0 to disable the connection timeout function.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the scaling factor for the speed monitor in the EtherNet/IP Class ID 2AH Object.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the scaling factor for the output current monitor in the EtherNet/IP Class ID 2AH
Object.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the scaling factor for the torque monitor in the EtherNet/IP Class ID 2AH Object.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the scaling factor for the power monitor in the EtherNet/IP Class ID 2AH Object.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the scaling factor for the voltage monitor in the EtherNet/IP Class ID 2AH Object.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the scaling factor for the time monitor in the EtherNet/IP Class ID 2AH Object.
V/f
CL-V/f
OLV
CLV
AOLV
Sets Output Assembly 116. The drive writes the values from Output Assembly 116 to
the Modbus address register that is stored for each parameter. The drive will not write
the values from Output Assembly 116 to the registers when the Modbus address is 0.
V/f
CL-V/f
OLV
CLV
AOLV
Sets Input Assembly 166. The drive sends the values from the Modbus address registers
stored for each parameter to Input Assembly 166. The drive returns the default register
value for the option card when the Modbus address is 0 and the value sent to Input
Assembly 166 is not defined.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Modbus address for PZD1 (PPO output). PZD1 (PPO output) functions as the
STW when F7-60 = 0, 1, or 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Modbus address for PZD2 (PPO output). PZD2 (PPO output) functions as the
HSW when F7-61 = 0, 1, or 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Modbus address for PZD3 (PPO output). A value of 0, 1, or 2 will disable the
PZD3 (PPO output) write operation to the Modbus register.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Modbus address for PZD4 (PPO output). A value of 0, 1, or 2 will disable the
PZD4 (PPO output) write operation to the Modbus register.
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Default
Ref.
(Range)
2
660
(0 - 2)
1
660
(0 - 8)
10
661
(10, 102)
0.0 s
661
(0.0 - 30.0 s)
0
661
(-15 - +15)
0
661
(-15 - +15)
0
661
(-15 - +15)
0
662
(-15 - +15)
0
662
(-15 - +15)
0
662
(-15 - +15)
0
662
0
662
0
662
0
662
0
662
0
663