Corrective maintenance
10.2 Replacing spare parts
10.Remove the current sensor (TX-20).
11.Remove the holding plate (TX-20).
The current sensor is removed.

Installing the current sensor

1. Mount the holding plate (TX-20).
2. Mount the current sensor (TX-20).
3. Mount the copper bar (TX-30).
4. Mount the copper bar (TX-30).
5. Plug the current sensor cables.
6. Mount the metal cover (TX-30).
7. Mount the metal cover (TX-20 and TX-30).
8. Mount the PE connect sheet metal (Hexagon 10 mm).
9. Connect the power cables (Hexagon 19 mm).
10.Mount the front cover.
11.Insert 2 screws (TX-25) of the front cover.
The current sensor is installed.