Parameters
7.3 Parameters
Note
AO: Analog Output
r0785.0...1

BO: CU analog outputs status word / CU AO ZSW

Access level: 3
Can be changed: -
Unit group: -
Min:
-
Description:
Displays the status of analog outputs.
Bit field:
Bit
00
01
Note
AO: Analog Output
p0791[0...2]

CO: Fieldbus analog outputs / Fieldbus AO

Access level: 3
Can be changed: T, U
Unit group: -
Min:
-200.000 [%]
Description:
Setting and connector output to control the analog outputs via fieldbus.
Index:
[0] = AO0 (X132 12/13)
[1] = AO1 (X131 26/X132 27)
[2] = Reserved
Dependency:
See also: p0771
Note
AO: Analog Output
The following interconnections must be established to control the analog outputs via fieldbus:
- AO 0: p0771[0] with p0791[0]
- AO 1: p0771[1] with p0791[1]
p0795

CU digital inputs simulation mode / CU DI simulation

Access level: 3
Can be changed: T, U
Unit group: -
Min:
-
Description:
Sets the simulation mode for digital inputs.
Bit field:
Bit
00
01
02
03
04
05
11
440
Signal name
AO 0 negative
AO 1 negative
Signal name
DI 0 (X133. 5)
DI 1 (X133. 6)
DI 2 (X133. 7)
DI 3 (X133. 8)
DI 4 (X133. 16)
DI 5 (X133. 17)
DI 11 (X131. 3, 4) AI 0
Calculated: -
Scaling: -
Unit selection: -
Max:
-
1 signal
Yes
Yes
Calculated: -
Scaling: PERCENT
Unit selection: -
Max:
200.000 [%]
Calculated: -
Scaling: -
Unit selection: -
Max:
-
1 signal
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Simulation
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
Data type: Unsigned16
Dynamic index: -
Function diagram: 9572
Factory setting:
-
0 signal
FP
No
-
No
-
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
Factory setting:
0.000 [%]
Data type: Unsigned32
Dynamic index: -
Function diagram: 2201, 2221,
2256
Factory setting:
0000 0000 0000 0000 bin
0 signal
FP
Terminal eval
-
Terminal eval
-
Terminal eval
-
Terminal eval
-
Terminal eval
-
Terminal eval
-
Terminal eval
-
SINAMICS G120XA converter