Advanced Settings - Siemens SINAMICS G120XA Operating Instructions Manual

Table of Contents

Advertisement

Exception: a mechanical coupling ensures that all of the motors always operate with the same
speed.
Table 6-72
Number
r0331[M]
p0346[M]
p0347[M]
p1201[C]
p1202[D]
p1203[D]
SINAMICS G120XA converter
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB

Advanced settings

Name
Actual motor magnetizing current / short-circuit current
Motor excitation build-up time
Motor de-excitation time
BI: Flying restart enable signal source
Flying restart detection current
Flying restart search rate factor
Advanced commissioning
6.8 Drive availability
Factory setting
- Arms
0 s
0 s
1
90% / 100%
150% / 100%
319