Corrective maintenance
10.2 Replacing spare parts
3. Disconnect the wires.
4. Remove the power supply.
The power supply is removed.
Installing the power supply
1. Mount the power supply on the top hat rail.
2. Connect the wires.
3. Install the front cover.
4. Insert 2 screws (torx 25) of the front cover.
Tightneing torque: 3 Nm.
The power supply board is installed.
10.2.4.5

Replacing the fuse for the external fan

Precondition
The converter power supply is switched off.

Required tools

● Torque wrench for TX-20 screws
● Torque wrench for TX-25 screws
● Slot screwdriver 0.6 mm × 3.5 mm