00
01
02
03
04
05
06
08
09
10
Note
OC: Operating condition
r0899.0...11

CO/BO: Status word sequence control / ZSW seq_ctrl

Access level: 2
Can be changed: -
Unit group: -
Min:
-
Description:
Display and BICO output for the status word of the sequence control.
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
11
Note
For bits 00, 01, 02, 04, 05, 06, 09:
For PROFIdrive, these signals are used for status word 1.
r0944

CO: Counter for fault buffer changes / Fault buff change

Access level: 3
Can be changed: -
Unit group: -
Min:
-
Description:
Display and connector output for the counter for changes of the fault buffer.
This counter is incremented every time the fault buffer changes.
Recommendation:
Used to check whether the fault buffer has been read out consistently.
Dependency:
See also: r0945, r0947, r0948, r0949, r2109
SINAMICS G120XA converter
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
ON/OFF1
OC / OFF2
OC / OFF3
Enable operation
Enable ramp-function generator
Continue ramp-function generator
Enable speed setpoint
Jog 1
Jog 2
Master control by PLC
Signal name
Ready for switching on
Ready
Operation enabled
Jog active
No coasting active
No Quick Stop active
Switching on inhibited active
Drive ready
Controller enable
Control request
Pulses enabled
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max:
-
1 signal
Yes
Yes
Yes
Yes
OFF2 inactive
OFF3 inactive
Yes
Yes
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max:
-
Parameters
7.3 Parameters
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
3001
No
3001
No
-
Data type: Unsigned16
Dynamic index: -
Function diagram: 2503
Factory setting:
-
0 signal
FP
No
-
No
-
No
-
No
-
OFF2 active
-
OFF3 active
-
No
-
No
-
No
-
No
-
No
-
Data type: Unsigned16
Dynamic index: -
Function diagram: 8060
Factory setting:
-
455