Parameters
7.3 Parameters
NOTICE
An ASCII table (excerpt) can be found, for example, in the chapter of parameters.
Note
Example: displaying the serial number for a memory card:
r7843[0] = 49 dec --> ASCII characters = "1" --> serial number, character 1
r7843[1] = 49 dec --> ASCII characters = "1" --> serial number, character 2
r7843[2] = 49 dec --> ASCII characters = "1" --> serial number, character 3
r7843[3] = 57 dec --> ASCII characters = "9" --> serial number, character 4
r7843[4] = 50 dec --> ASCII characters = "2" --> serial number, character 5
r7843[5] = 51 dec --> ASCII characters = "3" --> serial number, character 6
r7843[6] = 69 dec --> ASCII characters = "E" --> serial number, character 7
r7843[7] = 0 dec --> ASCII characters = " " --> serial number, character 8
...
r7843[19] = 0 dec --> ASCII characters = " " --> serial number, character 20
r7843[20] = 0 dec
Serial number = 111923E
r7844[0...2]

Memory card/device memory firmware version / Mem_crd/dev_mem FW

Access level: 2
Can be changed: -
Unit group: -
Min:
-
Description:
Displays the version of the firmware stored on the memory medium of the drive device.
Depending on the drive device being used, the memory medium is a memory card, or an internal non-volatile device
memory.
Index:
[0] = Internal
[1] = External
[2] = Parameter backup
Note
For index 0:
Displays the internal firmware version (e.g. 04402315).
This firmware version is the version of the memory card/device memory and not the CU firmware (r0018), however,
normally they have the same versions.
For index 1:
Displays the external firmware version (e.g. 04040000 -> 4.4).
For automation systems with SINAMICS Integrated this is the runtime version of the automation system.
For index 2:
Displays the internal firmware version of the parameter backup.
With this CU firmware version, the parameter backup was saved, which was used when powering up.
r7903

Hardware sampling times still assignable / HW t_samp free

Access level: 3
Can be changed: -
Unit group: -
Min:
-
Description:
Displays the number of hardware sampling times that can still be assigned.
These free sampling times can be used by OA applications such as DCC or FBLOCKS.
Note
OA: Open Architecture
670
Calculated: -
Scaling: -
Unit selection: -
Max:
-
Calculated: -
Scaling: -
Unit selection: -
Max:
-
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
Data type: Unsigned32
Dynamic index: -
Function diagram: -
Factory setting:
-
Data type: Unsigned16
Dynamic index: -
Function diagram: -
Factory setting:
-
SINAMICS G120XA converter